HomeMy WebLinkAboutBLD01-040~, O ~ V ~ WatennauffiKatz Building
~~ (~~0~ 181 Qnincy Sheet, Suite 201
o Port Townsevd, WA 98368
Phone: (360) 379-5083 Fax; (360) 385-4290
QL/ ~~' ~~
CITY OF PORT'"1"OWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-5083 for Inspection (Give at least one day notice)
Permit Number: BLDO1-O4O Issued: Apri15, 2001 Parcel Number: 936 901 803
Job Address: 601 53rd St. Zoning: R-I Type: V-N Occupancy: _ R-3
Total Occupant Load: 2 Nature of Work: Single-Family Residence w/detached Shop/Storage
Owner: Peter & Paulette Lack Contractor: Vernon Garrison
SPECIFIC CONDITIONS APPLY PER ATTACHED THREE PAGE PLAN CORRECTIONS
DATED 3/11/01 & 3/17/01 (Numbers 1-47) Calculations oj'desiQn loads & vertical loads design Nos.
9, 39 40 41 42 43 44 & 45 must be submitted on amended plans & approved prior to inspection.
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIILED:
• Electrical -Contact Labor& Industries @ 360-417-2702
REQUIRED INSPECTIONS -
Check all that Apply
APPRO VED/DATE
^ TEMP EROSION & SEDIMENT CONTROL
^ See General Condition No. 2
^ Silt Fence
^ Drive Off Mat to restrict sediment from leaving
the site
^ Other
^ F90TING5 t/ Sr~t~~ n.~~y c /y- 4~0~
Setbacks ~-< «~-
~ootings -
°~
orms -
Reinforcement -
^ Interior Footings
^ Porch Piers
L~UFER
^ Other
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
w
~~
REQUIREp INSPECTIONS APPROVED/DATE
L
Permit d BLDOl-040
C~OUNI2ATION ,~
4
i~o ~
LR" Stem Wall p lc~
~
L9~ orms
reinforcement
^ Engineered Holdowns
^/Anchor Bolts w/ 2" x 2" x 3/16" washers
C~/Foundation Vents - x required
C~ Crawl Space Access
^ Beam Pockets
^ Other
^ FLOOR FRAMING
^ Girder
^ Joists -Engineered BCI plan shall be on-site at
time of inspection
^ Blocking
^ Shield under Posts
^ Positive Connections
^ Girder to Concrete
^ Treated Wood to Concrete
^ Anchor Bolts w/ 2" x 2"x 3/16" washers
^ Foundation Vents -x required
^ Crawl Space Access
^ Other
^ PLUMBING:
^ Rough-In (D-V-T & Clean outs) _
^ Water Supply
^ Water Hammer Arresters
^ Hose Bibs (backflow protection required)
^ Pipe Insulation (R-3)
^ Pressure Reduction Valve if> 80 psi
^ Water Heater
^ Seismic Restraint - 2 places
^ Pressure relief valve drain to exterior, terminate
6" - 24" above ground
^ 18" AF.F.
^ Other
^ MECHANICAL
^ Whole House Fan -Utility Room
^ Source Specific Fans
^ Environmental Air Exhaust ducting (w/ backdraft
dampers), insulation (R-4) and terminus (located 3'
from opening)
Other
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
r~
.,p't
•
•
REQUIRED INSPECTIONS APPROVED/DATE
r'
~.
L
Permit # BLDOI-040
o FRAM~iG I
^ walls'
^ Engineered Shear Walls
Ceilings
^ Roof -engineered truss plan shall be on-site at
time of inspection
^ Truss Positive Connection
^ Attic Venting - eave and ridge
^ Windows -escape
^ Window safety glazing
~WIndOWS U factor - „~ c7 or better
NFRC window sticker must be on windows and
doors at inspection time
Air Seal
Fresh Air Intake (Window or Wall Ports required)
^ Doors U-Factor - or better
^ Fire Blocking
^ Weather Resistive Barrier
^ Other
ULARIION
OINS U..Rt~S £c.a o~c~G6-6-'G~
o
fS~Walls (R_ 19)
L'~Ceiling (R-30
~ Baffles
Vapor Barrier: faced batts
^ Crawl space - 6 mil black poly -
^ Other
^ DRY WALL NAILING
B'~Walls 6~~ ~- r~j-l~
Ceiling
^ Garage/House Occupancy Separation
^ Other
^ FINAL
^ Public works Si
n-Off
/~
g
^ House Numbers - 5"
^ Plumbing `Z//~ ~•1~ C I
/
^ MechanicaUHeating
^ Insulation Certificate
1~Smoke Detectors
^ Final -Building
I~, Other
i
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
{~
^~>
C~
i
Permi['~ BLD01-040
.~ /
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-5083. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required afrer inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-5083. A
. minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate_ of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact 385-5083 prior
to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
\t,~-~
R