Loading...
HomeMy WebLinkAboutBLD01-031! ~ CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Watemun ffi KmzBuilding 187 Quincy Sfree4 Suite 301 Pml Townmd, WA 98368 Phone: (360) 3793208 Faz: (360) 3B5-M75 CITY OF PORT TOWNSEND Permit Number. $LDO1-O31 Issued: 03/14/01 Parcel Number: 948-310-201 Job Address: 1203 13th Street Zoning: R-II Type: V_N Occupancy: R-3 Nature of Work: Construct unheated enclosed aorch and sunroomldinin¢ area Owner: Alan Dunham ContraMor: Rav Weber. GENERAL CONDTI'IONS APPLY -SEE LAST PAGE RF.nTTTRF.T) TNCPF,CTTnN4 APPRnVF,D/DATE TEMPORARY EROSION & SEDIMENT CONTROL See General Condition No 2, install on-site as needed during construction -okay to use existing driveway as construction entrance FOOTING Setbacks 3/ZZ~r~ /a/J ~/ Footings Forms Reinforcement ~~ FOUNDATION CMU Stem Wall ~/~ ~~~/ Forms Reinforcement FLOOR FRAMING ,,~ ~ ~ ~ ~ Joists ' ~ ~ ~ ~~' Blocking Positive Connections Treated Wood to Concrete Call 48 hours before you dig Tor utility line locates 1-800-424-5555 Page 1 of 3 Pemut M BI.DOI-031 REQUIRED INSPECTIONS APPROVED/DATE FRAMING Walls ~~ I~ Ceiling ~ r Roof Blocking Positive Connections Fire Blocking Weather Resistive Barrier FINAL House Numbers -check for 5" /„ ~ ~~ Smoke Detectors in existing house per 1997 ~ y' `y' UBC; one in each sleeping room and in each area leading to sleeping room with a minimum of one on each floor Final -Building GENERAL CONDTITONS 1. Contractors working on this project are required to have a Labor & Industries contraMor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site snd inspected prior to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance. Adjacent rights-of--way shall be kept free of dirt & debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to schedulint=. the Buildine Department's final inspeMion. 7. Final Inspections are required prior to occupancy. A Certificate of Occupancy is required fora non- residential project. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 Prnnit 8 BLDG]-031 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 f ~~