HomeMy WebLinkAboutBLD01-029wecerman ~ xstz aWta„~ tst coq siren, swk Sot Pat ToHmsmd, WA 98368 Phaw: (360) 379-31A8 Fug: (360) 385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDO1-O29R-1 Issued: 3/20101 Parcel Number: 988 800 806 Job Address: 877 Monroe Street Zoning: RR=II Type: VV=N Total Occupant Load: 513 Occupancy: R-3 /U-1 Nature of Work: Revision #1: Construct Detached Garaee Owner: Harold Purcell Contractor: L. D. Richert Construction, Inc. ****All elements of engineering including holdowns, framing, nailing and other engineered connections require inspection prior to cover**** GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 REQUIRED INSPECTIONS APPROVED/DATE TEMP EROSION & SDM'T CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Setbacks ~ ~J ~ ~ ~/,~a/ / ~/ Footings v~ fill// Forms Interior Footings R ' ement ~~ ~ a Call 48 hours before you dig for utility line locates I-800-424-5555 Page 1 of 4 Pemvt#HLI701-029R-1 RE UIRED INSPECTIONS APPROVED/DATE FOUNDATION Stem Wall Forms ~ / l Reinforcement ~ ~~ _~ / G/ Anchor Bolts & Washers - @ 36" o. c. per detail, sheet 9 / Engineered Holdowns SLAB Reinforcement Engineered Holdowns FLOOR FRAMING NOTE: Engineered BCI jloor joist plan to be on-site at time of inspection Joists Blocking Shield under Posts Positive Connections Treated Wood to Concrete Engineered Straps and Holdowns PLUMBING: Rough-In (D-V-T & Clean outs) Water Supply Hose Bibs (backflow protection required) Pipe Insulation (R-3) Pressure Reduction Valve if> 80 psi MECHANICAL Whole House Fan - F-2 bath Environmental Air Exhaust ducting (w! backdraR dampers}, insulation (R-4) and terminus (located 3' from opening) Call 48 hours before you dig for utility line locates I-800-424-5555 Page 2 of 4 Permit N BL7701-029R-1 REOUiRED INSPECTIONS APPROVED/DATE FRAMING: Walls Engineered shear walls Treated Wood to Concrete ~~~~` Engineered Posts, Beams & Headers Ceiling/Roof Rafter Positive Connection Roof Venting -ridge & eave Windows -escape Windows -safety glazing Fire Blocking Weather Resistive Barrier 7 ~J INSULATION Can verify insulation values, air seal, vapor barrier, etc. for future living space DRY WALL NAILING Walls Ceiling GaragelHouse Occupancy Separation FINAL L-i " • G . ~~n/~9 ~ `f~1~01i Plumbing `/ MechanicaVHeating Insulation Certificate Vapor Barrier Paint Certificate ~/ tO~~~Q7 I// ~L Smoke Detectors ~ Final -Building 1. Contractors working on this project are required to have a Labor & Industries contraMor's reeistration number and a City business license. Failure to provide proo! of this documentation prior to work may result in job shut down while this is accomplished. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. Ati elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your projeM until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3. A 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your. building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4 walmnan s x.~ewla~ IHI Qw~uy SYttI, S~o4 30l Port TowvenQ WA 93368 Phone: (360)3793208 Fax: (360)385-7675 CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE CaU 385-2294 for Inspection CITY OF PORT TOWNSEND Permit Number: BLDO1-O29 Issued: 3/19!01 Parcel Number: 988 800 806 Job Address: 877 Monroe Street Zoning: RlII Type: VV=N Total Occupant Load: 5/3 Occupancy: R-3 lU-1 Nature of Work: Construct Sinele family residence with attached earaQe Owner: Harold Purcell Contractor: L. D. Richert Construction, Inc. ****All elements of engineering including holdowns, framing, nailing and other engineered connections require inspection prior to cover**** GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 RE UIRED INSPECTIONS APPROVED/DATE TEMP EROSION & SDM'T CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Setbacks ~~~ 3~~ /rl/J ( f/ Footings 7 Forms Reinforcement Interior Footings Porch Piers UFER Ca1148 hours before you dig for utility line locates I-800-424-5555. Page 1 of 4 REQUIRED INSPECTIONS APPROVED/DATE Permit A BI.D01-029 FOUNDATION -foundation details, sheet 2 of plans " Stem Wall Forms Reinforcement ~'~~~Dv ` `~ Anchor Bolts & Washers - @ 36"and 16" o. c. per details, sheet 2 of plans Vents -12 required Crawl Access Beam Pockets Engineered Haldowns FLOOR FRAMING NOTE: Engineered BCI floor joist plan to be on-site at time of inspection Joists Girders Cripple Wall -shear wall per engineering, detail #4, sheet 2 Radiant Heat Tubing Blocking Shield under Posts Positive Connections Girder to Concrete Beam Pockets Treated Wood to Concrete Anchor Bolts and Washers - 36" & 16" o. c. PLUMBING: Rough-In (D-V-T & Clean outs) Water Supply Water Hammer Arrestor @ clothes and dishwasher Hose Bibs (backflow protection required) Pipe Insulation (R-3) Pressure Reduction Valve if> 80 psi Water Heater Seismic Restraint - 2 places Pressure relief valve drain to exterior, terminate 6" - 24" above ground MECHANICAL Boiler -installation instructions shall be on-site at Cj~~ / time of inspection ~O // Whole House Fan - F-2 bath Source Specific Fans Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from opening) Ca11 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 ~~ a etno~m~ REQUIRED INSPECTIONS APPROVED/DATE RAMING: ~ Walls Engineered shear walls ~ ~I ~~~, / ~ ~~ Treated Wood to Concrete ` Engineered Posts, Beams & Headers CeilingBoof-engineered truss plan shall be on-site at time of inspection Rafter/Truss Positive Connection Roof Venting -ridge & eave Windows -escape Windows -safety glazing Windows U-factor - .65 or better NFRC window sticker must be on windows and doors at inspection time Air Seal Fresh Air Intake (Wall Ports) Doors U-factor - .40 or better Fire B-ocking Weather Resistive Barrier ~ B~ INSULATION Floor - (R_] 99 ) Walls-(R~19) Ceiling - (R=30 ) Baffles Vapor Barrier: paint b mil black poly in craw] space DRY WALL NAILING Walls Ceiling FINAL Public Works Sign-Off House Numbers - 5" Plumbing Mechanical/Heating Insulation Certificate Vapor Bamer Paint Certificate Smoke Detectors ~ Final -Building ~ C ~ • Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 ., Permit#BLiJOI-029 I. Contractors working on this project are required to have a Labor & Industries contraMor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels. (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspeMions. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Cafl for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval rior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4