CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11 38 5-2 294 for Inspection
CITY OF PORT TOWNSEND
Permit Number: BLDO1-O24 Issued: 02/14/01 Parcel Number: 955900098
Owner/ContraMor: Hamilton Heiehts LLC Installer: Kozeliskv's Home Services WAINS0626
Job Address: Lot 98: 2697 Crest Avenue Zoning: PUD Type: VV=N Occupancy: R-3/U-1
Total Occupant Load: 512 Nature of Work; Set Manufactured Home w/ attached site-built aaraae
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
***Hours of Construction are limited to 7.•30 a.rrz to 6: 00 p.m. Monday through
Friday and prohibited on weekends and national holidays***
REQUIRED INSPECTIONS
Budding and Convnunity Developrtwd
Waterman & Katz Buildi~
181 Quincy Stied Suite 301
Port Townsend, WA 98368
Phone: (360)379.3208 Fax: (360)383-7675
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See details attached toMIP and general condition #2
Silt Fence
Drive Off Mat
SLAB/CONCRETE
Setbacks
~~Z/~
Forms
Monolithic Slab/Foundation (garage) ~/~D~~~
Reinforcement
Anchor Bolts
Alternate Braced Wall Panel Holdown Hardware
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Pmnit # BLD01-024 ,
nr, u1rc~U 1Nar~t;11VIVJ AYYRV VEll/llATE
PLUMBING (prior to skirting)
Water Supply -Main shut-off valve (port or ball valve)
installed in water supply piping prior to connection to home, min. ~/l s~~~
'/."diameter, same as supply pipe r
Pressure Reduction Valve if> 80 psi
Hose Bibs (backflow protection required)
Pipe Insulation -Outside & in crawl space
Pressure Test -100 p.s.i. for IS mimrtes
Pressure relief valve drain - to exterior of skirting, exhaust
downward between 6"and 24"above ground
Drainage Piping -sloped min. %. "per foot
MECHANICAL (prior to skirting)
Ducts & Duct Insulation
3/1$~g~ ~Q
Dryer Exhaust -vented to outside. Extension into crawl space ~(
requires venting through skirting with no dips; follow dryer
manufacturer's instructions; total combined length of ducting not
to exceed I4' w/ 2-90° elbows
FLOOR FRAMING (prior to skirting)
Anchors ~
/~"
Steel Support Piers -Load-stamped and installed per ~
~
t
manufacturer's installation manual; clearance of I8"min. from
lowest point of I-beam and the ground or footing for min. of 75%
of area under home w/ 12 "min. elsewhere unless installation
marmal specifies; otherwise area around home graded to provide
runoff away from home
FRAMING:
Engineered roof truss plan to be on-site at time of inspection /~
Walls /
Alternate Braced Wall Panels c
Header
Roof
Garage/House Attachment
DRY WALL NAILING
Garage/House Occupancy Sepazation w/20 minute self-closing
door
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
~~ '^'~ . _ ~_~_ ~ ~! ~ i _ _
ll ~_~~.
Permit # BLIl01-024
•
FINAL
Public Works Sign-Off
Electrical (L & I) Sign-Off
House Number - 5" numbers
Plumbing
Mechanical
Final -Building
No holes or gaps greater than '/, "allowed
in skirting. Skirting to be rated for contact with
earth if backf 11 is involved.
Crawl space ventilation per installation
marmal @ I sq. ft./ISO sq. ft. (16 req'd.);
located close to corners, on at least two
opposing sides for cross ventilation.
Crawl space access must provide access to
all areas under home; minimum 18" x 24"
unless specifred otherwise; covered with vinyl,
pressure-treated wood or metal.
GENERAL CONDTI'IONS
I. Contractors working on this project are required to have a Labor & Industries contractor's
reeistration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Soils exposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with
seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of
adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP} require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 3 of 4
Permit # HLDOl-024 '
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspeMion call 3852294; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within siz months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
C~
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4