Loading...
HomeMy WebLinkAboutBLD00-243 Permit Number: BLD00-243 Job Address: 939 Kearney Street Total Occupant Load: 26 Owner: Uotown Catering W akttnan & Katz Building 181 Quincy Skeet Sulk 301 Port Tow~uettd. WA 98368 (Phone) 379.3208 (Fart) 383-7673 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION STI'E Ca11385-2294 Tor Inspection Issued: 01/08/01 Parcel Number: 949818102 Zoning: CI Type: V_N Occupancy: M Nature of Work: Tenant Imurovement; no change of use Contractor: Rav Hulbert, business owner 385-0566 GENERAL CONDTCIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 Building Permit- Required for Type 1 Hood fire suppression system Plumbing Permit-Required for grease trap Sign Permit RF,niJiRF.D iNSPF.CTIONS APPROVED/DATE PLUMBING Drain Waste & Vent n~ Water Supply /(/`/ ~ . / /~ n ^ / (~ {/~/ 2 (GL Air Gaps @ food prep sinks and condensate drains ,` G Floor Drains require trap seal protection Water Heater - R-10 under if electric Grease trap requires separate Plumbing Permit MECHANICAL _ ,Gj ~ ~f ~~, //~/0, LPG Appliances - mamrfacturer's installation instructions shall be on-site at time of inspection ~ ~ (/'t`'~(' /~j~j " _ AppliancelExhaust Interlock II Exhaust Outlet Clearance - 2' above roof,• 5' other Type I Duct Gauge Duct JointslSeams -continuous liquid-tight weld Grease Duct Supports - no penetration of duct walls Duct Slope: '/,:12 Duct/Enclosure Separation-3"min.; 12"max. Duct Enclosure/Shaft -one-hour construction Cleanouts Page I of 3 Building PdmitpBLDa0243 ~ RE UIRED INSPECTIONS APPROVED/DATE MECHANICAL (continued) Air Velocity - ISOOfpm - 2500 fpm ~//~/0 Duct/Combustible Clearance -/8 "; 3 "from noncombustibles ` 1 G Hood Flashing -less than 12 "from ceiling or wall requires flashing with 22 gauge steel Duct Insulation -make-up air: R-3.3 Grease Filters -see UMC 508.5 and notes on plans Canopy Hood -installed per manufacturer's installation 7nShYlCtlOIJS FRA117ING Walls ~~~?~®~ /,n (`. (/ Ceiling l Doors -thresholds & lever hardware LIGHTING - no proposed changes DRYWALL NAILING ~iI/Q~ Walls /, Ceiling 1-hour shaft for Type 1 Hood. PARKING Contact John McDo»agh @ 379-5085 for inspection FINAL Fire Department Electrical (L&I) Health Department Plumbing Mechanical Building Exit Illumination (both exits) Door Signage (min. I" letters "This door to remain locked during Business hours" if locking hardware on Main Exit) Bamer-Free All Doors require lever type hardware. I-Van-Accessible Parking Space w/signage Page 2 of 3 Building Permit #BLD00343 GENERAL CONDTTIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required • inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3. A minimum of twenty four hours notice is required Public Works approval must be received prior to scheduling the Building Departments final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making changes in the field. Contact the Building Department @ 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Page 3 of 3