Permit Number: BLD00-243
Job Address: 939 Kearney Street
Total Occupant Load: 26
Owner: Uotown Catering
W akttnan & Katz Building
181 Quincy Skeet Sulk 301
Port Tow~uettd. WA 98368
(Phone) 379.3208 (Fart) 383-7673
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION STI'E
Ca11385-2294 Tor Inspection
Issued: 01/08/01 Parcel Number: 949818102
Zoning: CI Type: V_N Occupancy: M
Nature of Work: Tenant Imurovement; no change of use
Contractor: Rav Hulbert, business owner
385-0566
GENERAL CONDTCIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
Building Permit- Required for Type 1 Hood fire suppression system
Plumbing Permit-Required for grease trap
Sign Permit
RF,niJiRF.D iNSPF.CTIONS
APPROVED/DATE
PLUMBING
Drain Waste & Vent n~
Water Supply /(/`/ ~ . / /~ n ^
/ (~
{/~/
2 (GL
Air Gaps @ food prep sinks and condensate drains ,`
G
Floor Drains require trap seal protection
Water Heater - R-10 under if electric
Grease trap requires separate Plumbing Permit
MECHANICAL _ ,Gj ~ ~f
~~, //~/0,
LPG Appliances - mamrfacturer's installation
instructions shall be on-site at time of inspection ~
~
(/'t`'~('
/~j~j
"
_
AppliancelExhaust Interlock II
Exhaust Outlet Clearance - 2' above roof,• 5' other
Type I Duct Gauge
Duct JointslSeams -continuous liquid-tight weld
Grease Duct Supports - no penetration of duct walls
Duct Slope: '/,:12
Duct/Enclosure Separation-3"min.; 12"max.
Duct Enclosure/Shaft -one-hour construction
Cleanouts
Page I of 3
Building PdmitpBLDa0243 ~
RE UIRED INSPECTIONS APPROVED/DATE
MECHANICAL (continued)
Air Velocity - ISOOfpm - 2500 fpm ~//~/0
Duct/Combustible Clearance -/8 "; 3 "from noncombustibles ` 1 G
Hood Flashing -less than 12 "from ceiling or wall requires
flashing with 22 gauge steel
Duct Insulation -make-up air: R-3.3
Grease Filters -see UMC 508.5 and notes on plans
Canopy Hood -installed per manufacturer's installation
7nShYlCtlOIJS
FRA117ING
Walls ~~~?~®~ /,n
(`.
(/
Ceiling l
Doors -thresholds & lever hardware
LIGHTING - no proposed changes
DRYWALL NAILING ~iI/Q~
Walls /,
Ceiling
1-hour shaft for Type 1 Hood.
PARKING
Contact John McDo»agh @ 379-5085 for
inspection
FINAL
Fire Department
Electrical (L&I)
Health Department
Plumbing
Mechanical
Building
Exit
Illumination (both exits)
Door Signage (min. I" letters "This door to
remain locked during Business hours" if
locking hardware on Main Exit)
Bamer-Free
All Doors require lever type hardware.
I-Van-Accessible Parking Space w/signage
Page 2 of 3
Building Permit #BLD00343
GENERAL CONDTTIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
• inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3. A
minimum of twenty four hours notice is required Public Works approval must be received prior to
scheduling the Building Departments final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Page 3 of 3