HomeMy WebLinkAboutBLD00-232Watemmn &Katsl3uilding
181 Quiny Sired, Suila 301
Pet Towmerrd WA 98368
Phere: (360) 379-3208 Fu: (360) 38s-7676
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOO-232 Issued: 12/12/00 Parcel Number: 989712905
Job Address: 606 Calhoun Street Zoning: R-I Type: V_N Occupancy: R-3
Nature of Work: Single Family Residential Addition: Add Utility Room
Owner: John Wilcox
Contractor: All About Buildin8
GENERAL CONDITIONS APPLY -SEE LAST PAGE
RF(1TTTRFTI TNRPFfTT(lNR
LJ
APPRnVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2-inspection required
prior io foundation work.
Graveled construction entrance may be required to
prevent dirt and debris from leaving the site and
being tracked onto City rights-of--way
FOOTINGS ~
~r/0
Setbacks ~~
~ ~/
/
Footings
Forms.
Reinforcement
LIFER
FOUNDATION
Stem Wall Forms
Reinforcement
Anchor Bolts
Vents - 2 required
Crawl Access -through existing
ABWP Holdown Hardware
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Permit 71 BLD00.332
REQUIRED INSPECTIONS
APPROVF.D/IIATF.
FLOOR FRAMING
Joists
Blocking
Positive Connection
Treated Wood to Concrete
Anchor Bolts & Washers
PLUMBING
Rough-In (D-V-T & Clean Outs)
Water Supply
'~~'J (~ ~ b
`
Water Hammer Arrestor @ clothes washer Y
~
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
Seismic Strap (a3 I/3 points
Pressure Relief Valve Drain to exterior, elbow
down, terminate 6" - 24" above grade
MECHANICAL
Electric Forced Air.
Manufacturer's Installation Instructions to be
on-site @ time of inspection
Utility Room Fan n
~IL~O/ n/
Environmental Air Exhaust ducting, insulation `~ l (~
(R-4) and terminus (located 3' from opening)
FRAMING
Walls n n
S, /J _ . _ _^ Q, Z/~5 /Uj ('U
.(~~~ N~^"' / 6 ""ll..
Ceiling
Roof
Blocking
Positive Connection _ ^
~ 1 ~~~~'J
/ (
/
Attic Venting l
~
/
Window U-factor - .39 or better
Air Seal
Fire Blocking
Weather Resistive Bamer
INSULATION
Floor (R-30) /-,
3/~ /ly~
Walls (R-21)
Ceilings (R-38/R-30)
Baflles
Vapor Barrier :faced balls
6 mil black poly in crawl
~I
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
Pmnit # BIA04232
RE UIRED INSPECTIONS APPROVED/DATE
DRYWALL NAILING
Walls
Ceiling
FINAL
House Numbers - 5" minimum
Plumbing
Mechanical
Insulation Certificate (if applicable)
Smoke Detectors throughout existing construction
per 1997 UBC
Final -building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation
prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; call 385-2294, press 3. Measures shall include
• installation of silt fencing and graveled construction entrance (see attached details). Adjacent
rights-of-way shall be kept free of dirt debris. Soils exposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized
with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for
protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected, For Public Works inspection call 385-2294,
press 3. A minimum of twenty-four hours notice is required. Public Works aaaroval must be
received arior to scheduling the Buildin¢ Deaartment's final inspection.
7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required for a
non-residential project.
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 3 of 4
r~i a BL~oaxiz
8. All building permits expire if no progress has been made within six months, or if no inspections
are done by the Building Department within one year. Call for at least one inspection per year
to keep your building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Obtain revisions
from the Building Department (379-3208) prior to making changes to theappr~oved plans.
10. POST THIS PERMTT ON-STTE WITH THE APPROVED PLANS.
f~
U
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4