HomeMy WebLinkAboutBLD00-227Waterman & Kazz Building
l el Qwnry Sveet, Suite 307
Putt Townsend WA 98368
Phone: (360)379-3208 Fax: (360)385-7675
CITY OF PORT TOWNSENU
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOO-227 Issued: 11/22/00 Parcel Number: 948305402
Job Address: 1208 Gise Street Zoning: RR=H Type: VV=N Occupancy: RR_3
Nature of Work: Replace 17 windows and 4 sliding class doors in bedrooms 1 - 5, living room and
kitchen bath den hall rec room and dining room in existing rough oaeninQS.
Owner: William and Karen Bloemker
385-0544
Contractor: Groves & Co. Inc.
GENERAL CONDITIONS APPLY - 5EE LAST PAGE
REOiJIRED INSPECTIONS
•
APPROVED/DATE
FRAMING/FINAL:
Windows -safety glazing where applicable per
attached details.
Escape Windows -applicable in bedrooms if
enlarging existing window sizes
Window Ufactor - .40 or better (electric heat)
NFRC window sticker must be on
windows at inspection time
Air Seal
FINAL
Smoke Detectors throughout house per 1997
Uniform Building Code; battery powered
smoke detectors adequate in existing
construction
House Numbers -check for 5" high
Final -Building
CaII 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Pami[ #BLD00-227
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspeMed prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construMPon entrance (see attached details). Adjacent rights-ot way shall be kept free of dirt debris. Soils
exposed during construMion shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required. Public Works aoaroval must be received prior to
scheduline the Buildine Department's final inspection.
7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required for anon-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department Q 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
I-800-424-5555