Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD00-225
Watmman & Katz Building 181 Quincy Street, Suite 301 Pmt Townsend WA 98368 Phone: (360)379-3208 Fax: (360)3857675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDOO-225 Issued: 2114/01 Parcel Number: 948-319-202 Job Address: 834 Sheridan Avenue Zoning: P_1 Construction Type: V 1-hour Nature of Work: Remodel Former Office/CAT Scan Room to X-Rav Room Property Owner: Jefferson General Hospital Contractor/Owner: Same as Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE ELECTRICAL - a separate electrical permit is required for any electrical work. Contact Labor and Yndustries at (360) 417-2700 if needed. REQUIRED INSPECTIONS APPROVED/DATE MECHANICAL Air Handler Ducting Fire Stop Penetrations FRAMING -All engineered structural members and connections require inspection prior to cover Steel Columns HILTI C-20 Anchors Steel Base Plate Finish Rail Upper Rail Steel Beams T-BAR CEILING Class A Rated Ceiling Tiles Seismic Ties (if applicable) LIGHTING See attached NREC Compliance ,,~ J n~ r ~~ ©~ / l A l/,/ Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 ~i a shoo-ns FINAL Final -Fire Department Final - L & I Final -Mechanical Final -Shielding Envelope Fina! -Building g~~l~ ~ GENERAL CONDITIONS 1. Contractors working on this project are. required to have a Labor ~ Industries contraMor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call385-2294. Measures shall include installation of silt fencing and graveled construMion entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils exposed during construMion shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspeMion call 385-2294. A minimum of twenty-four hours notice is required. Public Works anoroval must be received prior to scheduling. the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800.424-5555 Yage 2 of 2 e - ~ ... .. ~.w . ~- ,~ ,. _ ,-- _ _ -