HomeMy WebLinkAboutBLD00-211Waterman and Katz Building 181 Quinry Street Suite 30l Port Townsend WA 98368 Plwne (360) 379-3208 Fax (360) 383.7675 • CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection CITY OF PORT TOWNSEND Permit Number: BLDOO-211R-1 Issued: 03/26/01 Parcel Number: 001-023-022 Job Address: 1143 Benton Street Zoning: R-11 Type: VV=N Occupancy: RR=3 Total Occupant Load: N/C Nature of Work: Revision #1: Reduce length of shear wall, F-2, NW corner to 30" ger revised eneineerin¢ Owner: Jonathan Stratman & Billie Judy Contractor: Same as Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REOUHiED: Electrical -Contact Labor & Industries @ 360-417-2702 FRAMING: Engineered Shear Wall @ F-2; use 15/32" CDXwith 8d nails 6" o.c GENERAL CONDITIONS I. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept Tree of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 Building Prnnit HBLD00.211 Rd 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca-1385-2294, press 3; a . minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval riot to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • Ca11 48 hours before you dig Tor utility line locates 1-800-424-5555 Page 2 of 2 i- 1 ~J Walen~n and Katz Building 181 Quincy S4eet Suite 30l Port Tmmsnd, WA 98368 Pltane (360) 379.3208 Fax (360) 383-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDOO-211 Issued: 12/14!00 Parcel Number: 001-023-022 Job Address: 1143 Benton Street Zoning: R-11 Type: VV=N Occupancy: RR=3 Total Occupant Load: add 2/2 Nature of Work: SF Residential Addition & Attached Garage Owner: Jonathan Stratman & Billie Judy Contractor: Same as Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE j, ~ [~~ ~-r ~,C~rn~~vG 1 SEPARATE PERMITS REQUIRED: ~/ 9/~ Zi Electrical -Contact Labor & Industries @ 360-417-2702 RFf1TTTRFTI 7NCPF.('TTnNC APPROVED/DATE • • TEMPORARY EROSION CONTROL See General Condition #2 Graveled driveway for construction entrance to prevent soil from being tracked onto City rights-of--way FOOTINGS Setbacks 2 ~ / Footings ~ ~ c .Forms Reinforcement -grade 60, #5 Porch/F-2 Piers Porch Stair Footings LIFER FOUNDATION Stem Wall ~ ! ~0, ~~ Forms Reinforcement Anchor Bolts - 5/8" ~j ~~ Vents - 3 required Crawl Access ,, L~ ~j "' " 9 Engineered Holdowns Simpson Strong Wall Holdowns @ garage Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 REQUIRED INSPECTIONS Building Permit pB1.D00.211 APPROVED/DATE FLOOR FRAMING -Engineered TJI plan to be on-site at time of inspection Joists Blocking Shield under Posts Positive Connection Treated Wood to Concrete Anchor Bolts and Washers PLUMBING Rough-In (D-V-T & Clean Outs) ~ ~(~~ ~ (,()~ / ~~/D~ Water Supply ' Pipe Insulation (R-3) Water Hammer Arrestor @ clothes washer Hose Bibbs (backflow protection required) Pressure Reduction Valve if pressure > 80 psi Water Heater - Seismic Straps @ I/3 points MECHANICAL Bathroom Fan / rl /, ~1I Whole House Fan ( ~ ~ L, / Uc Environmental Air Exhaust ducting (with backdraft ! dampers), insulation (R-4) and terminus (located 3' from openings) FRAMING: Walls Engineered Shear Walls // ~ ~ j ',j ~ ©2~ Simpson Strong-WaII Shear Walls @ garage (3) Shear Wall Nailing Shear Wa11 Straps Simpson CJTS post beam connector Ceilings Roof Attic Venting -ridge & eave Window -escape. Window U-factor:.33 or better; NFRC sticker on windows and doors at time oflnspection Window -safety glazing Air Seal Fresh Air Intake - window or wall ports required Doors U-factor -see attached WATTSUN Rafter/1'russ Positive Connection Fire Blocking Weather Resistive Barrier Ca1t 48 hours before you dig for utility line locates I-800-424-5555 Page 2 of 4 3 n C~ RF(1T1TRF.T) TNCPF.C'TTnNC Building Pmnit #BLD00411 APPRnVFA/DATE INSULATION Floor - (R-30) ~~ ~ ~~~~~ Wat-s - (R-19) ~ Ceiling - (R-30) Baffles Vapor Barrier -faced balls 6 mil black poly in crawl space DRYWALL NAII..ING Walls Ceiling trarage/House Occupancy Separation Enclosed Usable Space under Stairs FINAL House Numbers - 5" minimum Plumbing Mechanical Smoke Detectors throughout existing construction per 1997 UBC; battery powered okay Final -Building GENERAL CONDITIONS I. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Buildiig Permit kBLD00-211 6. The Building Department is unable to pass final inspeMion on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3; minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 arior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4