HomeMy WebLinkAboutBLD00-194way a„a xaa a~aa~
1st Quinsy sued Suite Sot
Pori Tow~end, WA 98368
Phone (360) 379-3208 Fax (360) 385-7675
•
•
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDOO-194 Issued: 03115(01 Parcel Number: 984901703
Job Address: 472 K Street Zoning: RR^II Type: VV=N Occupancy: UU=1
Total Occupant Load: NA Nature of Work: Construct 216 sf utility shed/ not for human occupancy.
Owner: Jens Coonenrath Contractor: Owner
(385-0694)
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF,OiJIRF,D INSPECTIONS
APPROVED/DATE
FOUNDATION
Wood foundation allowed on buildings less than 400sf
Not used for human occupancy.
Setbacks
FRAMING:
Walls
Roof
Ceilings
Posts, beams & headers
Windows -safety glazing
Fire blocking
Rafter Positive Connection
Weather Resistive Barrier
FINAL
Final -Building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Su~ding Petmil #BLD00-194
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
reeistration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspeMed
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt
and debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construMion is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4, Owner or owner's agent shall review and oversee correction of any and alt deficiencies noted by
required inspections.
5. Re-inspection isrequired after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294; a
minimum of twenty-fourhours notice is required. Public Works approval must be received prior to
scheduling the Building Department's fmal inspection.
7. Final Inspections and CertiLcate of Occupancy are required PRIOR to occupancy.
8. All building permits ezpire if na progress has been made within sia months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. Revisions require review and approval rior to making changes in the field. Contact the Building
Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
L~
Ca1148 hours before yon dig for utility line locates
1-800-424-5555
Page 2 of 2