Permit Number: BLDOO-Igg Issued: 10/27/00 Parcel Number: 999100186
Owner/Contractor: Prestiee Properties, Inc. Installer: Kozeliskv's Home Services WAIN50626
Job Address: 2110 Renee Place Lot 186, Towne Point Zoning: PUD Type: VV=N Occupancy: R-3/U-1
Total Occupant Load: 5!2 Nature of Work: Set Manufactured Home w/ attached site-built earaee/aorch
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RE UIRED INSPECTIONS
APPROVED/DATE
u
TEMP EROSION & SEDIMENT CONTROL
See details attached to MIP and general condition #2
Silt Fence
Drive Off Mat
SLAB/CONCRETE /~
~ 3f ~~
~
Setbacks ~~
`~
Forms
Monolithic Slab/Foundation (garage)
Footings/Runners
Reinforcement
Anchor Bolts
Engineered Holdown Hardware
UFER
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page I of 4
Pmnit # BID00.188
REQUIRED INSPEC'TinNS
APPRnVF.il/iIATF.
FLOOR FRAMING (prior to skirting)
Anchors ~~
/Z r
Steel Support Piers -Load-stamped and installed per l'
manufacturer's installation marmal; clearance of ]8" min. from
lowest point of I-beam and the ground or footing for min. of 75%
of area under home w/ 12 "min. elsewhere unless installation
manual specifies; otherwise area around home graded to provide
runoff away from home
PLUMBING:
Water Supply -Main shut-off valve (port or ball valve)
~ ~/~
installed in water supply piping prior to connection to home, min. I
°/. "diameter, same as supply pipe l
Pressure Reduction Valve if> 80 psi
Hose Bibs (backflow protection required)
Pipe Insulation -Outside & in crawl space
Pressure Test -100 ps. i. for I S minutes
Pressure relief valve drain - to exterior of skirting, exhaust
dowmvard between 6"and 24"above ground
Drainage Piping -sloped min. '/. "per foot
MECHANICAL
Ducts & Duct Insulation f ~~~ J,~,
Dryer Exhaust -vented to outside. Extension into crawl space ~
'~" (~`
requires venting through skirting with no dips; follow dryer
manufacturer's instructions; total combined length of ducting not
to exceed 14 ' w/ 2-90° elbows
FRAMING:
Engineered roof tn~ss plan to be on-site at time of inspection ~~/ /~
!
Walls
Engineered Shear Walls @ gazage
Header
Roof
Garage/House Attachment
DRY WALL NAILING
Garage/Iiouse Occupancy Separation w/20 minute self-closing ~~/~~®~
door
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
Permit # BI.DOO.188
Public Works Sign-Off
Electrical (L & I) Sign-Off
House Number - 5" numbers
Plumbing
Mechanical
~Z5/off
Porch
Final -Building
No holes or gaps greater than I/. "allowed
in skirting. Skirting to berated for contact with
earth if backfill is irrvolved
Crawl space ventilation per installation
manual @ 1 sq. ft./150 sq. ft. (1 S req'd.);
located close to corners, on at least two
opposing sides for cross ventilation.
Crawl space access must provide access to
all areas under home; minimum 18"x 24"
unless specifred otherwise; covered with vinyl,
pressure-treated wood or metal.
•
GENERAL CONDITIONS
I. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294, press 3. Measures shall include installation of silt
fencing and graveled construction entrance (see attached details). Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized
with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for
protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 3 of 4
Pemut # BLD00-188
6. The Building Department is unable to pass fmal inspection on your project until Public Works •
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4