Permit Number: BLDOO-1g6 Issued: 10/06/00 Parcel Number: 958 200 409
Job Address: 2003 Kuhn Street Zoning: RR=II Type: V-N Total Occupant Load: 3
Occupancy: R-3 Nature of Work: Construct Sinele family residence
Owner: Michael Barlev and Joanie Beldin Contractor: Same as Owner
****All elements of engineering including holdowns, framing, nailing and
other engineered connections require inspection prior to cover****
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF.nTTTRF.T) TNSPF.('.TTnNS
APPROVED/DATE
TEMP EROSION & SDM'T CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site -see SUD permit #00-034
GROUNDWORK PLUMBING
Pressure Test ~/~ ~
Pipe Joints Exposed
Pipe Bedding
FOOTINGS
Setbacks
Footings ~ /Zl /~~ n /J
~!/ L/ (,_,
f'
Forms (
Reinforcement - (3) #4
Interior Footing
Porch P' rs
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Permit#HLD00.186
REOiTIRED INSPECTIONS APPROVED/DATE _'
FOUNDATION
Stem Wall
Forms n n ~
//
O/ (
~Z~
Reinforcement lam(
G
Anchor Bolts - @ 36 o.c. `
Engineered Holdowns
SLAB
Insulation
Ja/~$/O t
Radiant Floor Tubing
FLOOR FRAMING
NOTE: Engineered BCI floor joist plan to be on-site
at time of inspection ~~
Joists
Hydronic Tubing
Blocking ,
Shield under Posts
Positive Connections
Treated Wood to Concrete
Anchor Bolts and Washers
PLUMBING:
Rough-In (D-V-T & Clean outs) „n
jj1,Ul~ E (,(/ S 7/2 3l o ( f` +
(f
-
Water Supply ~
,
'
Gas Supply
Water Hammer Arrestor @ clothes and dishwasher
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
Seismic Restraint - 2 places
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
ME
i er -instal atr`an instructions shall be on- ' at
r~ i~ //~/~
time of inspection; requires low water shut-o,~'' 4 ~% 1
hut-o
Whole House Fan -Upstairs Bath
Source Specific Fans
Environmental Air Exhaust ducting (w/ backdraft
dampers), insulation (R-4) and terminus (located 3'
from opening)
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
Pmnit#BLD00-186
s
RRCITITRF.T) TNSPF.CTTnNS APPROVED/DATE
FRAMING:
Walls -engineered panel walls
Treated Wood to Concrete
~
~~1~/~1
(/
Engineered Posts Beams & Headers
Ceiling
Roof .
RafterlTruss Positive Connection -per engineering
Roof Venting
Windows -escape
Windows -safety glazing
Windows U-factor - .60 max.
NFRC window sticker must be on windows and
doors at inspection time
Air Seal
-Fresh Ai~- r Intake" ~ ow Port ,
rs ---
Fire Blocking
Weather Resistive Barrier
INSULATION
Radiant Slab (R=10 )
Walls (R-22 stress skin panel }
Ceiling (R-30 stress skin ganel )
Vapor Barrier: paint
WALL NAILING :~l
u/! ~ ~~
O
Walls `
l
Ceiling ,
FINAL
Public Works Sign-Off
Fire Department Sign-Off (LPG)
House Numbers
Plumbing
MechanicaUHeating
Vapor Barrier Paint Certificate
Smoke Detectors
Final -Building ~ f ' y7 j
f [~!~' i-
r~
Call 48 hours before you dig for utility line locates
1-500-424-5555
Page 3 of 4
Permit # BLD00-186
t
(:FNF.RAT. CONDTTTONS
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TE5C) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspeMed. For Public Works inspection ca11385-2294, press 3. A
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-
residential project.
8. All building permits expire if no progress has been made within siz months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active
4. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208} prior to making changes to the approved plans.
10. POST THIS PERMIT ONSITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4