Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD00-181
Waterman &. Katz Building 187 Quinry Street. Swte 301 Port Toumsmd. WA98368 Phone: (360) 379-3208 Fax: (360) 385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDOO-181R-2 Issued: 4112/01 Parcel Number: 965700010 Job Address: 1233 Blaine Street Zoning: RR=II Type: VV=N Occupancy: R-3/ Ul Nature of Work: Revision #2• chance heat source to electric heat from orouane; chance size and number of windows for WSEC compliance Owners: Eric & Marv Toews (uurchased from Ian Keith/ GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 RF.OTTTRFI) TNSPF,CTTnNS Contractor: TIR Coruoration APPRO VED/DATE FRAMING: Heat source changed from propane to electric *esistance -see attached compliance form indow U-factor .33 NFRC label to be on windows at time of inspection Windows -egress Windows -safety glazing FINAL -see original permit/inspection record Final -Building . Call 48 hours before you dig Tor utility line locates 1-800-424-5555 Page 1 of 2 1 _-~ Pemti[ k BI.D00-161 R-2 GENERAL CONDTITONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twenri-four hours notice is required. Public Works aooroval must be received urior to scheduling the Building Department's final inspection. • Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All. building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making changes in the field. Contact the Building Department @ 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2 wetem,zn ~ x~ ewtamq I81 Quincy St[ee4 Suite 301 Port'iownaend, WA 98368 Phone: (360)379-3208 Fex: (360)385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MiTST BE POSTED AT CONSTRUCTION STTE Call 385-2294 for Inspection Permit Number: BLDOO-I8IR-1 Issued: 11/16/00 Parcel Number: 965700010 Job Address: 1233 Blaine Street Zoning: R-II Type: VV=N Occupancy: R-3/U-1 Nature of Work: Revision #1• substitute 3-0 door on east side for 6-0 door on the south side; Owner: Ian Keith Contractor: TIR Corporation 385-2704 GENERAL CONDITIONS APPLY -SEE LAST PAGE RE UIRED INSPECTIONS APPROVED/DATE See original inspection record Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 Yemtit#BLD00.le3R-7 GENERAL CONDITIONS 1. Contractors wonting on this projeM are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TE5C) measures shall be installed on-site and inspected prior to beginning construction;. ca11385-2294.. Measures shall include installation of silt fencing and graveled construction entrance. Adjacent rights-of--way shall be kept free of dirt & debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction. is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your projeM unfit Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A Final Inspections are required prior to occupancy. A Certificate of Occupancy is required for anon- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2 Walmnan & Rate Building 181 Quincy Street Suite 301 Pat Towroend, WA 98368 PMM:(360)379-3208 Faz: (360)385.7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDOO-igl Issued: 10/06/00 Parcel Number: 965-700-010 Job Address: 1233 Blaine Street Zoning: RR=H Type: V-N Occupancy: R-3/U-1 Total Occupant Load: 7/4 Nature of Work: Construct single-family residence w/~ara~e Owner: Ian Keith Contractor: TIR Corporation GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 RF.f1TTTRF.TI TNCPF.C'TTnN~ APPROVED/DATE TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 -Inspection required prior to footings Silt Fence Drive OfI'Mat to restrict sediment from leaving the site FOOTINGS ~A&2D3~~, ~~~/pp Setbacks Footings Forms Reinforcement Interior Footings Balcony Footings -see attached engineering UFER Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 5 Permit M BLDOD.IBj i REQUIRED INSPECTIONS APPROVED/DATF. FOUNDATION Stem Wat( Forms Reinforcement Anchor Bolts w/ 2" x 2" x 3/16" washers Foundation Vents - 4 required Crawl Space Access Engineered Holdowns Waterproofing ~lOd.! ~ (;~1" %15'f-+~ Wac.c- ((/quad 1 ~ ~ ~ nl I~/~Q~ LOQX,( bt(j ~ FLOOR FRAMING Engineered BCI joist plan to be on-site at time of inspection Girders CZ15/~ Joists d Blocking Shield under Posts Positive Connections Engineered Floor Ties Girder to Concrete Positive Connection Post-to-Foundation Wall Treated Wood to Concrete Anchor Bolts w/ 2" x 2"x 3/16" washers Foundation Vents PLUMBING: Rough-In (D-V-T & Clean outs) ^ „ +// j~l~©r / Water Supply ~ Water Hammer Arrestor at clothes and dishwasher Gas Supply ~ y /®~ nn Bibs ackflow rotection required) ~ J (_l / G Pipe nsulation (minimum R-3 l ` Pressure Reduction Valve if > 80 psi Water Heater Seismic Restraint - 2 places Pressure relief valve drain to exterior, terminate 6" - 24" above ground Ca1148 hours before you dig for utility line locates i-800-424-5555 Page 2 of 5 Permit k BLD00-18I !, J RE UIRED INSPECTIONS APPROVED/DATE (yIES~HANICAL G fireplace LPG Heaters ouse Fan -Bath Source Specific Fans Environmental Air Exhaust ducting (w/back draft l~~©, !! dampers), insulation (min. R-4) and terminus (located 3' from opening) FRAMING NOTE: Engineered Shear Walls ~ ~ ~ 3~~fl Walls Ceilings f n ~~ Roo Rafter Positive Connection ,/ j°~~ , ~" ' /~ ' - Attic Venting ridge and eave v 1 , Windows -escape Window safety glazing Windows Ufactor - .65 maximum NFRC window sticker must be on windows, doors and skylights at inspection time Skylights Air Seal Fresh Air Intake (Window Ports) Doors U-Factor - .40 max. Fire Blocking Weather Resistive Barrier INSULATION ~ 2~! u/ ~'Z~ ~"G Walls (R=19) Ceiling (R=30 ) Battles Vapor Barrier: vapor barrier paint Crawl space - 6 mil black poly DRY WALL NAILING , ,~ 1 '~`~ Walls _ ,~ ~- Ceiling Enclosed space under stairs Garage/House Occupancy Separation CHIMNEY Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 5 ra„„t u sinoiisi '.. • 8. All building permits ezpire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active.. 9. Revisions require submittal and approval rior to making changes in the Feld. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 5 of 5 C~, - • Pemtil k BLD00-181 FINAL Public Works Sign-Off Fire Department Sign-Oft' (LPG) LPf~ ~~0' /)// House Numbers - 5" ~/~// Plumbing Mechanical/Heating Insulation Certificate Vapor Barrier Paint Certificate Smoke Detectors Balcony Deck/Stairs/Porch Final -Building 1. Contractors working on this project are required to have a Labor & Industries contractor's registration • number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering. including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A minimum of twenty-four hours notice is required. Public Works aaproval must be received prior to scheduline the Buildine Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certi£cate of Occupancy is required for anon- residential project. Call 48 hours before you dig for utility line locates I-800-424-5555 Page 4 of 5 ~~ ,r u