HomeMy WebLinkAboutBLD00-164r. _ ~~ Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone.(360)379-3208 Faz: (360)385-7675
C~
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD~O-164
Job Address: 1341 48th Street
Issued: 09/21/00 Parcel Number: 998-800-905
Zoning: R-I Type: VV=N Occupancy: R-3
Total Occupant Load: 3 Nature of Work: Construct sinEle-family residence
Owner: Joseah Ha1liQan and Tamara McEvers Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF.OTTTRF.D TNSPECTIONS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2 and attached Street and
Utility Development Permit
Silt Fence
Drive Off Mat to restrict sediment from leaving
the site
FooTINGS
Setbacks /D/l7/00
~-
Footings /
Forms
Reinforcement
Interior Footing
Porch Piers
UFER
u
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
rtr~xaewao.~cq
REQUIRED INSPECTIONS APPROVED/DATE
' S
FOUNDATION
Stem Wall
Forms ( r~ ~
`('~~~ ~ 6®~ `-~
Reinforcement
Alternate Braced Wall Panel Holdowns
Anchor Bolts w/ 2" x 2" x 3/16" washers
Vents - 6 required
Crawl Access
FLOOR FRAMING
Joists - Fargineered BCI plan shall be on-site at time
~ f I~7~~ n
of inspection j l.i(,
Blocking
Positive Connections
Treated Wood to Concrete
Anchor Bolts w/ 2" x 2"x 3/16" washers
Foundation Vents
PLUMBING:
-
Rough-In (D
V-T & Clean outs) ~w, / ~ I , I S (~ /~
It v
/~
Water Supply V
[,
Water Hammer Arresters @ clothes and dishwasher
Gas Supply
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
Water Heater
Seismic Restraint - 2 places
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL /~
n
LPG Stove - verb hig
ciency for .75 windows f
/
/J
h
Whole House Fan -Lau Room ~
~
O /
/
/ ! l/%I /
Source Specific Fans `
(
Environmental Air Exhaust ducting (w/ backdraft
dampers), insulation (R-4) and terminus (located 3'
from opening)
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 2 of 4
I-
RF,nTiTRF,T) TNSPECTTnNS APPROVED/DATE
Permit#BLW4160
f FRAMING
Walls
~
~
Ceilings ~
~
~~ ~
Roof- pre-engineered truss plan shall be on-site at ,
time of inspection
Attic Venting - eave and ridge
Windows -escape
Window safety glazing
Windows Ufactor - .75 or better
NFRC window sticker must be on windows and
doors at inspection time
Air Seal
Fresh Air Intake (Window Ports)
Doors U-Factor - .40 or better
Fire Blocking
Weather Resistive Barcier
INSULATION
Floor (R=19) `~~ p/ ~/~//o~
(~(/ (l l
Walls (R_19 )
Ceiling (R_30 )
Baffles
Vapor Barrier: paint
6 mil black poly in crawl space
DRY WALL NAILING
Walls q
~~~tf~a~~ ~~/
Ceiling l
!fi
Enclosed Usable Space under Stairs t
FINAL
Public Works Sign-Off
Fire Department Sign-Off (LPG)
House Numbers - 5"
Plumbing
Mechanical/Heating
Insulation Certificate
Vapor Barrier Paint Certificate //O~
Z /Jn
Smoke Detectors ~
O
(`
%
Final -Building f
•
Ca1148 hours before you dig for utility tine Locates
1-800-424-5555
Page 3 of 4
. ,~
~~8~~_~~
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TE5C) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3. A
acncuunne ,uc yw~uure Ycya~ uucm ~ uum mavca.uuu.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits ezpire if no progress has been made within siz months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility liue locates
I-800-424-5555
Page 4 of 4