HomeMy WebLinkAboutBLD00-156Waluman ~ Ka.tzBwlding
Iel Quincy Street, Suite 30l
Pon Townsend, WA 98366
Phone: (360)379-3208 Fu: (360)365-7675
•
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDOO-156
Job Address: 1194 57th Street
Issued: 8/16/00 Parcel Number: 972-905-204
Zoning: R_H Type: VV=N Occupancy: R-3
Total Occupant Load: 2 Nature of Work: Construct single-family residence
Owner: Sarah Grossman/Jennifer Carl Contractor: Discovery Bav Construction
GENERAL CONDITIONS-APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical- Contact Labor & Industries @ 360-417-2702
• RF,CITJTRF,TI TNSPF.('"I'Tl7NS
APPR nVF'T)/I)A TF,
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS
Setbacks
Footings
Footing at deck curb
Pilaster footing and reinforcement @ girder per
architect's detail 3, sheet 3 of 4
Forms
Reinforcement
Interior Footings - 2 " x 2 " x 8" w/ (3) #4 each way
Porch Piers
UFER
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Permit d Bf,U00-156
RE UIRED INSPECTIONS APPROVED/DATE
FOUNDATION
Stem Wall
Forms ~
~ r ~,v r `.U 9 I S/
Reinforcement - - #4 @ 10 ' o.c. honzontal wrth (2) l
#4 continuousat top ofwall; #4 @ Iti"o.c.
vertical, alternate hooks
Pilaster @ girder
Anchor Bolts - 5/8" anchor bolts @ 4' o.c.
Foundation Vents - 7 required
Crawl Space Access
FLOOR FRAMING
Girder
~
~ (,~~,I'L/~
Joists -Engineered BCI plan shall be on-site at time ~
ll 1177 ~~
Of tnSpeCtlOn
Blocking
Shield under Posts
Positive Connection
Girder to Concrete
Treated Wood to Concrete
Anchor Bolts w/ 2" x 2"x 3/16" washers
Foundation Vents - 7 required
Crawl Space Access
PLUMBING:
Rough-In (D-V-T & Clean outs)
Water Supply
Gas Supply
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
Water Heater
Seismic Restraint - 2 places
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL
LPG Heater
Whole House Fan -Utility Room
Source Specific Fans
Environmental Air Exhaust ducting (w/ backdraR
dampers), insulation (R-4) and terminus (located 3'
from opening)
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
Pmnit#HLD00-156
~•
i
G
RF.OTTTRFD TNSPECTIONS APPROVED/DATE
FRAMING
Walls
Sheathing -block all panel edges per engineering
Ceilings
Roof- engineered truss plan shall be on-site at time
of inspection
Truss Positive Connection
Attic Venting -gable ends
Windows -escape
Window safety glazing
Windows Ufactor - .50 or better
NFRC window sticker must be on windows, doors
and skylights at inspection time
Skylights - .47 U-factor
Air Seal
Fresh Air Intake (Wall Ports)
Doors U-Factor -see attached WATTSUN
Fire Blocking
Weather Resistive Barrier
INSULATION
Floor (R_30) ~
Walls (R=19 ) ~
~ Ceiling (R-30 )
Battles
Vapor Barrier: paint
Crawl space - 6 mil black poly
DRY WALL NAILING
Walls - %s" GWB nailed @ 7" o.c. with Sd cooler 1~/~/~~
nails per engineering
Ceiling
FINAL
Public Works Sign-OlI'
~ Z/ ~OD
Fire Department Sign-Off (LPG)
House Numbers - S"
Plumbing
Mechanical/Heating
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detectors
Final -Building
• Call 48 hours before you dig for utility line locates
1-800-424-SSSS
Page 3 of 4
Pemtit N BLD00.156
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt
debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
{ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required afrer inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3. A
minimum of twenty-four hours notice is required Public Works aRaroval must be received nrior to
scheduline the Buildine Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required. fora non-
residential project.
8. All building permits expire if no progress has been made within siz months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
A Revisions require submittal and approve! nrior to making changes in the field. ContaM the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 4 of 4