HomeMy WebLinkAboutBLD00-154
M
wainman a xa~ swlmng
I81 Quvuy Stree4 Suim 301
Port iawmrnd, WA 98368
Phone: (3h0)379-3208 Fax: (360)385-7614
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOO-IS4R-1 Issued: 2/02/01 Parcel Number: 948-308-008
Job Address: 1426 Cleveland Street Zoning: RR=H Type: VV=N Occupancy: R-3
Total Occupant Load: 2 Nature of Work: Construct ADU in basement of SFR
Owner: Robert DeBerrv Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
REQUIRED INSPECTIONS
APPROVED/DATE
PLUMBING:
Rough-In (D-V-T & Clean outs)
Watet Supply
Water Hammer Arresters @ clothes and dishwasher
Gas Supply
~l ~e-j
Hose Bibs (backflow protection required) /~/
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
R-10 under
Seismic Restraint - 2 places
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL
LPG Heater /////
Whole House Fan Z
o/
l 77
Source Specific Fans
Environmental Air Exhaust ducting (w/ backdraft
dampers), insulation (R-4) and terminus (located 3'
from opening)
Call 48 hours before you dig for utility tine locates
1-800-424-5555
Page 1 of 3
Permit N BLD00.154R-1 ~ t
REQUIRED INSPECTIONS
APPROVED/DATE
FRAMING -one-hour fire resistive construction
required beriveen dwelling u»its
Walls
Ceilings
Windows-escape
French Doors - .48 U-factor
2'~~1~~ - 11
`-'~J
Windows Ufactor - .34 U-factor
NFRC window sticker must
be on windows and doors at inspection time
Air Seat
Fresh Air Intake (Window Ports)
Doors U-Factor - .40 or better
Fire Blocking
Weather Resistive Barrier
INSULATION t
Walls (R=19) ~~~~1
Vapor Barrier: paint
DRY WALL NAILING -one-hour fire resistive
construction between dwelling units „ ! ~' l/D
~
Wa11s %Al
[G
Ceiling
FINAL
House Numbers - 5"
Plumbing
MechanicaUHeating
Insulation CeRificate - if applicable
Vapor Barrier Paint Certificate
Smoke Detectors
Final -Building
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
-- - ~ - -ems ---..---
Pmnit X BL-Od154R-!
1
. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils ezpased during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible far protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall paneis
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A
minimum of twenty four hours notice is required Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required Fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building.
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Pale 3 of 3
_~
-- ~ -' ~°`,` ~-tea 1._,
-- -
~.
"~1~..~ ..,,,y..r- a, -
P•
Watemlan & Kmz Builmng
181 Quinsy Strce4 Suite 301
PoM1 Towucnd, WA 98368
Phone: (360)379-3208 Fax: (360)385-76J6
CITY OF PORT TOWNSEND
•
CONSTRUCTION PERMIT & INSPECTION RECORD
TffiS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOO-IrJ4 Issued: 8/28/00 Parcel Number: 948-308-008
Job Address: 1424 Cleveland Street Zoning: R`II Type: VV=N Occupancy: R-3
Total Occupant Load: 5 Nature of Work: Construct sinele-family residence
Owner: Robert DeBerrv
Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF.OUiRF,D INSPE("TIONS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2 and attached Street and
Utility Development Permit #00-044
Silt Fence
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS
Setbacks ,,,~~~///~~~
~ ~~
~
Footings j
Forms
Reinforcement
Engineered Interior Footings
Porch Piers
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
a
Permit K HLD00.156
RE UIRED INSPECTIONS APPROVED/DATE
FOUNDATION
Stem Wall ,/
f~rK/~
Forms
. Reinforcement
Engineered Holdowns
Anchor Bolts w/ 2" x 2" x 3/16" washers
Waterproofing
FLOORFRAMING / /
Engineered Beams and Headers ~ (
/ 3
Joists -Engineered BCI plan shall be on-site at time /
oflnspection ) of
C~ROVND l~B'+t°~ ~Ulw~~N~ ~/~r~jCl~
Blocking
Positive Connections
Treated Wood to Concrete
Anchor Bolts w/ 2" x 2"x 3/16" washers
PLUMBING:
Rough-In (D-V-T & Clean outs)
(J,vp~npouNp ~L(~N-~~N~ ~(~~
Water Supply
Water Hammer Arresters ~ clothes and dishwasher.
Gas Supply
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
Water Heater
R-l0 under
Seismic Restraint - 2 places
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL
LPG Heater
Whole House Fan -Floor-2 Baih
Source Specific Fans
Environmental Air Exhaust ducting (w/ backdraft
dampers), insulation (R-4) and terminus (located 3'
from opening)
i
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 2 a[ 4
Permit # HLD00.154
u
RF.(1TTTRF.1) TNCPFC'.TT(1NS APPROVED/DATE
FRAMING
Walls
~ ~~(~
Engineered Shear Walls
Engineered Straps
Ceilings
Roof- see engineering
Engineered Rafter Connections
Attic Venting - eave and ridge
Windows -escape
Window safety glazing
Windows Ufactor - .45 or better
NFRC window sticker must be on windows and
doors at inspection time
Skylights U-factor - .68 or better
Air Seal
Fresh Air Intake (Window Ports)
Doors U-Factor - .40 or better
Fire Blocking
Weather Resistive Barrier
INSULATION , /
Floor (R=25) ~~
/~
Walls (R_19) G
Ceiling (R-30 vault/R-38 attic )
Baffles
Vapor Barrier: paint
DRY WALL NAILING ~/ ///
Walls C..~ l7/ 4~
Ceiling / L
Enclosed Usable Space under Stairs
FINAL
Public Works Sign-Off
Fire Department Sign-Off (LPG)
House Numbers - 5"
Plumbing
Mechanical/Heating
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detectors
Final -Building
Call 48 hours before you dig for utility line locates
i-800-424-5555
Page 3 of 4
Pvmit ~ BLDO0.154
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a Ciri business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A `~
minimum of twenri-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final insuection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fors non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval erior to making changes in the field." Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT OPI-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4