CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDUU-I4~R-2
Job Address: 814 Van Buren Street
Tata! Occupant Load: N/C
Owner: Mareuerite Cadwell
Issued: 11/08/00 Parcet Number: 965-702-504
Zoning: R;II Type: VV=N Occupancy: R-3
Nature of Work: Revision #2: Kitchen Remodel
Contractor: S & S Construction
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
nL-nrrrosn rttreD~!'~Til1NC
APPRnVF.n/I)ATF, /
See also original inspection record
PLUMBING
Rough-In (D-V-T & Clean Outs)
Water Supply
Pipe Insulation (R-3)
Pressure Reduction Valve if pressure exceeds 80 psi
Water Heater
R-10 under if elctric
Strap tank at 1/3 points with bottom strap minimum 4"
above controls
Pressure relief valve drain to outside, elbow down, with
termination 6" - 24" above ground
MECHANICAL
Bathroom Fan -environmental air exhaust ducting (with
backdraft damper), insulation (R-4), and terminus (located
3' from openings into building)
FRAMING:
Walls Z/Z 3~~
Air Seal
Fireblocking
Ca[I 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
4 `
Pmnit k BLIJ00.190R-2 '
Y '
REQUIRED INSPECTIONS
APPROVED/DATE
INSULATION
Exterior Walls (fill exposed cavities )
DRY WALL NAILING
Walls
Ceiling (if applicable)
Vapor Barrier (e.g., V. B. paint/faced insulation) is
required on warm side of exterior walls
FINAL -see also original inspection record
House Numbers -check for 5" numbers /
~n
Smoke Detectors -existing residence to be ~ ~ ~
~
/ 1"Y~
l
upgraded for smoke detectors per 1997 UBC [
1/
Final -Building
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of-way shall be kept Tree of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to coven
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspecton report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Permit k BLD047a0R3
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required far a non-
. residential project.
S. All building permits expire if no progress has been made within six months, or if no inspections are done
by fhe Building Department within one year. Call far at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the $uilding
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
CaII 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
CITY OF PORT TOWNSEND
Waterman 6<Katz Building
181 Quincy Street. Suite 301
Port TownaeM, WA 96368
Phone: (360)379-3208 Fez: (360)385-7675
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOO-I4OR-1 Issued: B/ll/oo Parcel Number: 965-702-504
Job Address: 814 Van Buren Street
Total Occupant Load: N/C
Nature of Work:
Owner: Mar¢uerite Cadwell
Contractor: S & S Construction
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUII2ED:
Electrical -Contact Labor & Industries @ 360-417-2702
See original permit for other inspections.
RF(1TTTRF,1) TNSPF,(,TTnNS
APPROVED/DATE ,.
FRAMING: May be done at final if all elements A /~ ~~~,~- ~~~,~'_ ~ /~j /~'CI
'
are exposed for inspection. / ~-
,
Ledger Fastening
Roof
Blocking
FINAL
See original permit for final inspection
C~
Zoning: RR=II Type: VV=N Occupancy: R-3
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Permit#HLD00-140R-I ' ~
C..NF.RAI. CONDiTiONS
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required. Public Works apnroval must be received prior to
scheduling the Building Departments final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-
residential project.
8. All building permits expire if no progress has been made within siz months, or if no inspections are done
by the .Building Department within one year. Call for at least one inspection per year to keep your
building permit active..
9. Revisions require submittal and approval urior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
Waterman $ Ktlz Building
IBI Quincy Stwet. Suite 301
Pon Towmend, WA 98368
Plrone: (360)379.3208 Faz: (360j 385-7675
CITY OF PORT TOWNSEND
i
CONSTRUCTION PERMIT & INSPECTION RECORD
', THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: I3LD~~-14~
Job Address: 814 Van Buren Street
Total Occupant Load: N/C
Owner: Marguerite Cadwell
Issued: 7/18/00 Parcel Number: 965-702-504
Zoning; RR=Ii Type: VV_N Occupancy: R-3
Nature of Work: Residential reaair and remodel
Contractor: S & S Construction
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
T?Ti'l1TTfl2FTl TN.CPF.f TTf1N.C
APPRnVF.n/DATE
DEMOLITION
Materials from demolition are to be transported to
Jefferson County Landfill or other approved off-site
location meeting all qualifrcations of state and local
law
MECHANICAL
Bathroom Fan -environmental air exhaust ducting
(R-3), insulation (R-4), and terminus (located 3'
from openings into building)
FRAMING: ,q~~
Walls - replacement as needed of rotten sills !'.kF,/~3 ,Q~tG~¢Z N t Jl~~
Windows -safety glazing 7
Window U-factor - .65 or better
NF'RC slicker shall be on windows and doors at
I zll~~~~
time of inspection
Air Seal
Flashing
Doors U-factor
Weather Resistive Barrier
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Y
Permit M BLD00-190
REQUIRED INSPECTIONS APPROVED/DATE
INSULATION
Exterior Walls (fill exposed cavities ) ~~ ~j
DRY WALL NAILING
N/A -all exterior work
FINAL
Siding
House Numbers „~}
Smoke Detectors -existing residence to be 2~Z ~
~ d~ l(
J'
/
upgraded for smoke detectors per 1997 UBC .
L
i
Final -Building
1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration
number and a Ciri business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
i
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent.rights-of-way shall be kept free of dirt
debris. Soils ezposed during construction shall. be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
{ABWP)Yequire inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3. A
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fors non-
residential project.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Pemtit #BL-00-140
• 8. All building permits ezpire if no progress has been made within siz months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig Tor utility line locates
1-800-424-5555
Page 3 of 3