HomeMy WebLinkAboutBLD00-135w.~ ~ xarzsvildo~
I81 Quinry Strte~ Soi1e 301
Port Townsend, WA 98368
Plwne: (360)379-3208 Fax: (360)385-7675
CITY OF PORT TOWNSEND
- CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: I;LD~O-13Jr
Issued• 7124100
Parcel Number: 966-600-305
Job Address: 2393 Logan Street
Zoning: R-11 Type: V-N
Occupancy: R-3/U-1
Total Occupant Load: 712 Nature of Work: Construct Single-family Dwellin>z with saraee
Owner: Micfiael and Linda Thomsett Contractor: B & D Constrnction
Bob Fitzpatrick 385-4451/301-0973 cell
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
****All engineered details require inspection prior to cover****
RE UIRED INSPECTIONS
APPROVED/DATE
TEMP EROSION & SDM'T CONTROL
See General Condition #2
Silt Fence as needed per street development
Drive OffMat to prevent sediment from leaving
the site
FOOTINGS -
Setbacks
Footings
Forms
Reinforcement
Continuous Interior Footings
Porch Piers
UFER
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 1 of 5
Pumit # BLDW133
REQUIRED INSPECTinNS APPRnvRnmAT F.
FOUNDATION
Stem Wall
Cripple Wall
Forms
Reinforcement
Anchor Bolts w/ 2" x 2" x 3/16" washers
Vents - 20 required
Crawl Access
Engineered holdowns
FLOOR FRAMING
NOTE: Engineered TJI joist plan shall be on-site jor the
inspector at inspection time ~ ~ ~/ G
Z 3 f c/
Joists
Cripple Wall & Sheathing
Blocking
Positive Connection
Treated Wood to Concrete
Anchor Bolts & Washers
FDN Vents -10 required
PLUMBING:
Rough-In (D-V-T & Clean Outs)
J ,,~~y~/~
~
~~
Water Supply 1
(I
C7V
Gas Supply
Water HammerArrestor Qa clothes & dishwasher ~
~ ~ /~~
Hose Bibs (backflow protection required) ~
6
lation -3
Pressure Reduction Valve if> p
Water Heater
R-10 under if electric
Seismic Restraint - strap Q 1/3 points
18" A. F. F.
Pressure relief valve drain to exterior;
6" - 24" above ground
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 5
r~~asLnoo-tas
= 'RFf1TTTRFTI TNCPT+`~'FiCINC APPROVED/DATE
i
ECHAHICAL
ropane Furnace -manufacturer's installation
instructions to be on-site ai time of inspection
Combustion Air
Exhaust _- -
_~_ -- -
uct n tasu o - R-8
LPG Fireplace
Whole House Fan -master bath
Source Specific Fans
Environmental Air Exhaust ducting (with
Backdraft dampers), insulation (R-4) and
Terminus (located 3' from opening)
<1 /~ ~ J~ ~~
/ ,,
F
N E: Engineered nailing for shear walls
l
'requires inspection prior to cover
Wa
Engineered Shear Walls
Roof -engineered truss plan to be an-site at time
of inspection / _
~ ~-/ ~~~~~~~
Engineered Roof Sheathing ``-"
Attic Venting -gable end & eave
Ceilings
Engineered garage header
Windows -escape
Windows -safety glazing
Windows Ufactor - .65 or better
NFRC window sticker must be on
windows & doors at inspection time
Air Seal
Fresh Air Intake (window)
Door UFactor - .40 or better
Rafter/Truss Positive Connection
Fire Blocking
Weather Resistive Barrier
INSULATION °
~~1~~~~~
~
L'~G-.' ~~
Floor (R-19) ~
~.
Wall (R-19 )
Ceiling (R-30 )
Baffles
Vapor Barrier: paint
Crawl Space - 6 mil black poly
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 5
Pe'mN q BLD00-135
REQUIRED INSPECTIONS APPROVEn/DATE
DRY WALL NAII.ING
Walls-
Ceiling
Garage/House Occupancy Separation
Engineered Interior Braced Walt Panels
~,//~~
'7`'
CHIMNEY
Termination
Chimney Cap
Spark Arrester
FINAL
Fire Department Sign-Off (LPG tank and exterior piping) J
r~/mA /)~
Public Works Sign-Off /
1 ! ~I l-C
House Numbers - 5"
Plumbing
Mechanical/Heating ///, ~D~ „n
Z `r! ("r CV
Insulation Certificate .
Vapor Barrier Paint Certificate
Smoke Detectors
Final -Building
GENERAL CONDITIONS
L .Contractors working. on this project are required to have a Labor & Industries contractor's re¢istration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished..
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt
debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any. and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 5
r~~,~t a aLOOO-tss
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one-year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 5 of 5