HomeMy WebLinkAboutBLD00-133Watamsn & Katzfluilding
181 Quinty Strttl, Suite 301
Pon Tawmend, WA 98368
Planc: (360j 379-3208 Fan: (360)385-7675
CITY OF PORT TOWNSEND
•
CONSTRUCTION PERNIIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number:. I3LDUU-133 Issued: 7/7/00 Parcel Number: 001-043-024
Job Address: 2633 Iw Street Zoning: RR=II Type: V-N Occupancy: R_3
Nature of Work: SFR Kitchen Addition with Deck.
Owner: Paul and Jean Nolette
Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RE UIRED INSPECTIONS
APPROVED/DATE
FOOTINGS
Setbacks
Footings
Forms
Reinforcement
Porch Footing '~~
~/ 3f ~ t'(
FOUNDATION
Stem Wall ~~
~~~~/Mc ~
Forms
Reinforcement
Anchor Bolts & Washers
Vents - 3 required
Alternate Braced Wall Panel Holdown Hardware
FLOOR FRAMING
Joists 1~~~ f~ /~
` ( -
Blocking ~
Positive Connection
Treated Wood to Concrete
Anchor Bolts & Washers
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Pentit KBLDW-133
RE UIRED INSPECTIONS APPROVED/DATE
PLUMBING /
Rough-In (D-V-T & Clean outs) f ~6 ~~~
Water Supply
Water Hammer Arrestor at dishwasher
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
MECHANICAL ~ ~/~
Kitchen Fan
Environmental Air Exhaust dulling (w/ backdraft
dampers), insulation (R-4) and terminus (located 3'
from opening)
FRAMING
Walls 1®`~0~~ ~ ~/
(.,~
Ceiling
Roof
Attic Venting - at eave
Window U-factor - .65 or better
NFRC Iabe1 shall be on windows at time of
Inspection
Air Seal
Door U-factor - .40 or better
Truss Positive Connection
Fire Blocking
Weather Resistive Barrier
, ~n
~St~S ~G~1711~/f~ ~ l q LL~
!0 l ~OD
DRY WALL NAII.ING
Walls
~ ~J/2 D,D~ ('p
`"
Ceiling ~
FINAL
House Numbers -check for 5" numbers
Plumbing
MechanicaUHeating
Smoke Detectors throughout
Final -Building
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
u
P~~ aatooa~ss
•
ENERAL CONDITION
I. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2, Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A
minimum of twenty-four hours notice is repaired. Public Works aaaroval must be received urior to
schedulin¢ the Building Department's 5nal inspection.
7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required fora non-
residential project.
8. All building permits ezpire if no progress has been made within siz months, or if no inspections are done
6y the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department aQ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3