HomeMy WebLinkAboutBLD00-119Wolermen & Kota Building
181 Quinq Stree4 S Wle 301
Port Townsend, WA 98368
Phone: 3603793208 Fe: 3 6 0 38 3-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOO-119 Issued: 6/21/00 Parcel Number: 989703904
Job Address:- 1038 Water Street Zoning: C-HI Construction Type: VV=N
Occupancy: AA=3 Total Occupant Load: NA Use of Building: Restaurant
Nature of Work: Install three (31 retractable awninQS above front windows.
Owner: Pacific & Artic. Inc. dba The Public House
Contractor: NW Awnin¢ & Fabrication. Inc. (206) 285-2941
GENERAL CONDITIONS APPLY - 5EE LAST PAGE
RF,OiTiRF.D iNSPECTiONS
APPROVED/DATE
FRAMING
Attach each awning frame to building wood
frame members with 3/819 a 3" lag screws, two
on each end and at top, and each awning arm
to wood frame members with'/," a 3" lag
screws, two on each. See attached drawing.
FINAL
HPC Color requirements -red or buff awning
color approved.
NOTE: Framing Inspection may be done
at Final Inspection ijall elements are
visible
Call 48 hours before you dig for Utility line locates
1-800 424-5555
Page 1 of 2
Petxni[ H BLD00-119
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
Contractor's Registration Number and a City Business License. Failure to provide proof of
this documentation PRIOR to work may result in job shutdown while this is accomplished.
2. TESC -Temporary erosion and sediment control measures shall be installed on-site and
inspected prior to beginning construction; cai1385-2294, press 3.1Vleasures shall include
installation of silt fencing and graveled construction entrance (see attached details). Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc., once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All engineered elements including sheathing, nailing, holdowns, ABWP's (alternate braced
wall panels), etc., requires inspection PRIOR to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after Inspection Report corrections are completed.
6. The Building Department is unable to pass Final Inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294, press 3. A minimum of 24 hours notice is required. Public Works approval must 6e
received prior to scheduling tfie Building Department's Finat Inspection or issuing a
Temporary Certificate of Occupancy.
7. Final Inspection and Certificate of Occupancy (nonresidential only) required PRIOR to
occupancy.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST TffiS PERMIT ON-5TTE WITH THE APPROVED PLANS.
Call 48 hours before you dig for Utility line locates
1-800 424-5555
Page 2 of 2