HomeMy WebLinkAboutBLD00-114Waterman 8c Katz Building
181 Quincy Street Suite 301
Port Towmend, WA 98368
Phone (360)385-7609 Fez (360)385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOO-1 ~4 Issued: 8/07/00 Parcel Number: 951-909-501
Job Address: 4250 Elmira Street Zoning: RR=II Type: V;N Occupancy: R-3
Total Occupant Load: 2
Owner: Haden Starbuck
Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF.f1TTTRF.TI TNRPF.fTTONS
APPRnVED/DATE
TEMP EROSION & SEDIMENT CONTROL
Inspection required prior to footings -See General
Condition No. 2
Silt Fence
Drive Off Mat to restrict sediment from leaving
the site
GROUNDWORK PLUMBING / „G~
,cl.fl
Pressure Test ~
l (/ i CT v
Pipe Joints Exposed
Pipe Bedding '
SLAB
Setbacks /
~(~ r/~
Forms
Monolithic Slab Foundation
Thickened Footings
Reinforcement
Anchor Bolts & Washers
Insulation -R-10 @ perimeter and under entire slab
Radiant Heat Tubing
UFER
Nature of Work: Construct single-family residence
Page 1 of 4
Huildioe Pemilt /BLD00.11a
REQUIRED INSPECTIONS APPROVED/DATE
INSULATION
Slab (R=10)
Walls (R_21)
Ceiling (R-30 vault )
Baffles
VaporBamer: paint (walls)/plastic (ceiling) (~'
~v ~`.~~~
~ ~ ~ \
DRY WALL NAILING / /
/) Q
Walls ~
®,
/ ("r,Y
(~f
Ceiling ~
l
f
FINAL
Public Works Sign-Oft'
House Numbers - 5" numbers ~ / ¢~
Plumbing !i/ 7i °~~
Mechanical/fleating
Insulation Certificate
VaporBarrier Paint Certificate
Smoke Detectors
Final -Building
I. Contractors working on this project are required to have a Labor & Industries contractor's. registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be.kept free of dirt
debris. Soils eaposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All .elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed
Page 3 of 4
Building Permit MBLD00-114
•
RR(1TTTRF.T) TNSPF,CTTnNS APPROVED/DATE
PLUMBING:
Rough-In (D-V-T & Clean outs),
Water Supply
Water Hammer Arrestor @ clothes and dishwasher
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
Seismic Restraint - Z places
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
I Z j1~ /~
l (/
MECHANICAL
Boiler -installation instructions shall be on-site at / ~ // /
l J'- D~
time of inspection; requires low water shut-off and r
high temperature shut-off
Whole House Fan -Bath
Source Specific Fan @ kitchen
Environmental Air Exhaust ducting (w/ backdraft
dampers), insulation (R-4) and terminus (located 3'
from opening)
FRAMING
Walls
~ Z~~~/Qb
Positive Connection l
Treated Wood to Concrete
Ceilings
Roof
Rafter Positive Connection
Roof Venting -gave & ridge
Windows -escape
Skytight U factor -:.58 or better
Door U-factor - .20 or better
Windows Ufactor - .36 or better
NFRC window sticker must be on windows,
skylights and doors at inspection time
Air Seal
Fresh Air Intake (Window & Wall Ports)
Fire Blocking
Weather Resistive Barrier
Page 2 of 4
Building Pvmit YBLD00-114
b. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits ezpire if no progress has been made within siz months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval orior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approvedplans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Page 4 of 4