HomeMy WebLinkAboutBLD00-113Walertnan & Kate Buildh~g
181 QWrory 6tree4 Suite 301
Port row0aeod. WA 96366
Phone: 360379J308 Fo:360J85-7675
CITY OF PORT TOWNSEND
~1
U
•
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD00-113 Issued: 617/00 Parcel Number: 965702203
Job Address: 1640 Lincoln Street Zoning: RR=II Type: V-N Occupancy: RR=3
Total Occupant Load: NC Nature of Work: Residential Remodel
Owner: Garv & Sally Baird
Contractor: Same as Owner
GENERAL CONDITIONS APPLY: See last cage
SEPARATE PERMTTS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
UTt (1TiTAFTI iNCPF!'Ti~INC
APPRnVF.n/nATF.
FOOTINGS , ~ ~ ~~~
~
~
~
Setbacks - NC (
j/
Footings I
Forms
Reinforcement
Interior Footings
Porch/Deck Piers
FOUNDATION PLE WALL
2" x 4" pressure treated wall framed with solid
blocking or 2" x 6" pressure treated wall
'/s" plywood with 6" o.c. nailing (cry edges, 12" o.c. in
field, one side minimum
FOUNDATION
Stem Wall - 8"
Forms
Z/~/((~
Reinforcement
Anchor Bolts & Washers
Crawl Access
Foundation Vents - 9 required
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page I of 4
Building Permit #BLD00.113
REQUIRED INSPECTIONS
APPRnVF:n/nATF.
J
FLOORFRAMING -- - - - -
Joists
Blocking
Positive Connection
Treated Wood to Concrete
Crawl Space Access
Foundation Vents - 9 required
PLUMBING
Drains, Vents, Traps and Ctean Outs
Water Supply yt~$ Qjl7rOb
Pipe Insulation (R-3) l
Pressure Reduction Valve if pressure > 80psi
Water Heater
Strap @ 1/3 points Z/q/D~
/
Pressure relief valve drain to exterior, elbow down,
terminate 6" - 24" above grade
MECHANICAL
Source Specific Exhaust Fans / (
[ d l ~ ~~
Environmental Air Exhaust ducting (with backdraft
dampers), insulation (R-4) and terminus (located 3
feet from openings into building)
FRAMING ~
Walls (~~ 2 ~ ~
~
Ceiling
Roof
Rafter/truss positive connection
Attic venting -ridge and eave
Posts, beams and headers
Windows -safety glazing
Windows U-factor - .65 or better
NFRC sticker must be on windows, doors and
skylights at time of inspection
Air Seal
Fireblocking
Weather Resistive Barrier
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
Building Permit #BLD00-113
INSULATION
Floor (fill existing joist cavities) l~' J~~(~
Walls (R-19/existing: fill exposed cavities)
Ceiling (R-30)
Baffles ~,I `~/3~ ~ /~
~(/Q~ ~ ((~('
Vapor Barrier -backed balls
6 mil black poly in crawl space
DRYWALL NAILING
Walls ~~ l/`/~-0
~/`
Ceiling
FINAL
House Numbers - 5" numbers ~f~~~ _ /)
/
///
Plumbing ~
Mechanical
Insulation Certificate (if applicable)
Smoke Detectors throughout existing construction
per 1997 UBC
Final -building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a Ciri business license. Failure to provide proof of this documentation
prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294, press 3. Measures shall include installation of silt
fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be
kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with
mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings,
sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent
properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Building Permil #BLDa0.113
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your. project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294,
press 3. A minimum of twenty-four hours. notice is required. Public Works approval must be
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a
non-residential project.
8. All building permits ezpire if no progress has been made within six months,. or if no inspections
are done by the Building Department within one year. Call far at least one inspection per year to
keep your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555