HomeMy WebLinkAboutBLD00-098Waterman&ICatxBuilding
181 Quinry Stnx1, Suite 301
Pon 1'ownend, WA 96368
Phone: (360) 3A-3208 Fu: (360) 385.7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Owner: Dan Harbin Contractor: Same as Owner
Permit Number: BLDOO-09g Issued: 5!31100 Parcel Number: 957901001
Job Address: 1510 HaStInQS Avenue Zoning: R-2 Type: V-N Occupancy: R-3
Nature of Work: Construct New Foundation For ADU Occupant Load: 1
(See MIS00-016 for moving permit)
GENERAL CONDITIONS APPLY -SEE LAST PAGE
NOTE: FOUNDATIONPERMIT ONLY
RE UIRED INSPECTIONS
APPROVED/DATE
TEMP EROSION & SDM'T CONTROL
See General Condition No. 2 -install on-site as needed
during construction to prevent sediment from leaving the
site and to eliminate tracking of soil onto the street
FOOTINGS ~J
Z~/~~
Setbacks ~
`mil
Footings
Forms
Reinforcement
Interior footings
UFER
FOUNDATION
Stem Wall
~ ~/Z ~~~
Forms
Reinforcement
Anchor Bolts w/ 2" x 2" x 3/16" square washers
Vents - 4 required
Crawl space access
Girder to Concrete
Beam Pockets
Positive Connection
Treated Wood to Concrete
Shield under Posts
6 mil black poly
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Permit # BLD00.096
FINAL /Vof f~~ 1C oti >'07. ~ l
House Number -check for 5" numbers rv ~- y„ ~ u n.,r,doc.s
Smoke Detectors required throughout existing
house per 1997 UBC: one in each sleeping room
and in each area/hallway leading to each sleeping /
room with a minimum of one detector on each floor !/
Final -building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior
to beginning construction; call 3852294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, eta once construction is
completes Applicant is responsible Tor protection of adjacent properties.
i
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A
minimum oftwenty-four hours notice is repaired. Public Works auoroval must be received prior to
scheduling the Building Department's final inspection.
Final Inspections are required prior to occupancy; a Certificate of Occupancy is required for anon-
residentialproject.
8. All building permits ezpire if no progress has been made within siz months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Obtain revisions from the
Building Department (379-3208) prior to making changes to the approved plans.
30. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2