HomeMy WebLinkAboutBLD00-080City of PoR Townsend I8l Quincy Street Suite 30L Port Townsend, WA 98368 Phone (360) 379-3208 Fax (360) 383-7673 CITY OF PORT TOWNSEND BUILDER'S PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDOO-O8OR-1 Parcel Number: 957602401 Issued: 07118!00 Job Address: 2427 Washineton Street (behind New Dav Fisheries) Zoning: M-11A Occupancy: UU=2 Nature of Work: Revise anchor bolt pattern for construction of new vole design Owner: Voice Stream Wireless Contractor: TBD GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMTTS REQUIRED: ELECTRICAL (WA State Labor and Industries) NOTE• Special Inspection required for reinforcement and concrete (4.000 psi! by independent testing IabaratorV Der engineer's structural notes. Special Inspection Reports shall indicate compliance with the plans and specifications and shall be copied to the Building Department in a timely manner Permit Holder or Permit Holder's Anent shall review and oversee correctionof any and all deficiencies noted by required special inspections. RE UIRED INSPECTIONS APPROVED/DATE FOUNDATION (4) 2.25"diameterASTMA-615 bolts, 12' long attached to top and bottom templates, 9.5" bolt projection above foundation with'/."separation between bolt and rrut FINAL (see original permit card for /~ ~ -other required inspections) Final-Building GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Re-inspections are required after any corrections are complete. Call 48 hours before you dig for utility locates 1-800-424-5555 Page 1 of 2 auilding Permit #8LD00-080Rd 3. Final Inspections and approvals are required. 4. All Building Permits expire if no progress has been made within six months or, if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your permit active. 5. Revisions require review and approva3 rD 10C to making changes in the field. Contact the Building Department at 379-3208 prior to making changes to the approved plans. 6. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility locates 1-8MM24-5555 .~ Page 2 of 2 City of PoR Touvseud 181 Qui~y Street Suite 301 Port Townund, WA 98368 Phone (360) 379-3208 Fax (360) 383-7673 CITY OF PORT TOWNSEND BUILDER'S PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for htspecGon Permit Number: BLD00-080 Parcel Number: 957602401 Issued: 05/24/00 Job Address: 2427 Washineton Street (behind New Dav Fisheries) Zoning: M-11A Occupancy: U_2 Nature of Work: Construction of 75-foot monopole with antenna array: fenced enclosure with concrete slab for eauioment cabinets Owner: Voice Stream Wireless Contractor: TBD _~ GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMTTS REQUIRED: ELECTRICAL (WA State Labor and Industries) NOTE: Special Inspection reauired for reinforcement and concrete /4.000 psi) b independent testinP laboratory per engineer's structural notes. Special Inspection Reports shall indicate compliance with the plans and speci/ications and shall be copied to the BuilrlinP Department in a timely manner. Permit Holder or Permit Holder's Agent shall review and oversee eorrecdonof any and all deficiencies noted by reauired special inspections. 1L FOUNDATION Footing 5' x 26 ; 1 footA.G. with 6"chamfer Reinforcement -grade 60 (16) #9 vertical bars spaced equally circular ties, 4 "clearance from bottom and sides: "b" _ #4 @ 6" o.c. with 22"lap "a" =~i4 @ 4" o.c. with 22"lap Anchor Bolts (8) 2.25"diameterAS7MA-615 bolts, 7' long attached to top and bottom templates, 1 'bolt projection above foundation with ~/."bolt thread above nut ~9~ao Call 48 hours before you dig forutility locates 1-800-424-5555 Page 1 of 2 Building Prnnit #BLD00.080 RE UIRED INSPECTIONS APPROVED/DATE POLE Color samples shall be submitted to the BCD Director for approval prior to COl7st7'uctlOrl alldpalYltl7Jg SLAB (equipment support) Reinforcement -see sheet a-4 of plans #4 Q 12" o.c. each way FENCE & GATE -see sheet a-4 of plans Post Hole Posts & Stringers ~~~ !l~ „ n / ! / J 1 Simpson CB44 with (2) 5/8^ bolts ~ V Simpson FB24 fence brackets FINAL ~ ~ p D ~ Final-Building / GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Re-inspections are required after any corrections are complete. 3. Final Inspections and approvals are requ'ved. 4. All Building Permits expire if no progress has been made within six months or, if no inspections have been made by the Building Department within one yeaz. Call for at least one inspection per year to keep your permit active. 5. Revisions requireseview and approval prior to making changes in the field. Contact the Building Department at 379-3208 prior to making changes to the approved plans. 6. POST THIS PERIVIIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for atility locates 1-800-424-5355 Page 2 of 2