HomeMy WebLinkAboutBLD00-071Waterman & Katz Building
l81 Quinry Street Suite 301
Purl Townsend, WA98368
(Phone) 379-3208 (Fax) 383-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDOO-O71 Issued: 4/21/00 Parcel Number: 989704201
c~ RYnS
Job Address: Water and er treets Zoning: CIII Type: V-N Occupancy: B
Total Occupant Load: N/C Nature of Work: Construct new transit shelter
Owner: Jefferson Transit Authority
Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
""lYQTE: Permit for new shelter is issued conditioned upon City Council approval: change of location
requires permit revision prior to construction"*
RROTTTRF.D TNSPF,CTTONS
APPROVED/DATE
DEMOLITION
Demolition materials shall be transported to the
Jefferson County Landfill or other approved facility
in accordance with all state and local laws and
ordinances
CONCRETE
Anchor Boot System Q Posts
- anchor boot
- wedge anchors
FRAMING
Internal Connections
- Rivets
- Frame Clips
- Hex Bolts
Window Safety Glazing
Page 1 of 2
Building Permit #BI,D00.071
RE UIRED INSPECTIONS APPROVED/DATE
FINAL
Barrier-Free ~/~ /_ ~+~~
Building Vim(
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsib-e for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required aker inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected For Public Works inspection call 385-2294, press 3. A
minimum of twenty-four hours notice is required. Public Works aoorovsl must be received nrior to
schedulingthe Building DevartmenYs Tinal insnectionBuilding Devartment's Tinal inspection.
7. Final Inspections. are required prior to occupancy; A Certificate of Occupancy is required for anon-
residentialproject.
8. All building permits ezpire if no progress has been made within siz months, or if na inspections are done
by the Building Department within oae year. Call. for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department Q 379-3208 prior to making. changes to the approved plans.
10. POST THIS PERMIT ONSTI'E WITH THE APPROVED PLANS.
Page 2 of 2
Watenuen & Katz Building
181 Quincy Streit Suite 301
Part Townsend, W A 98368
(Phone)379.3208 (Faz)383-7673
•
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOO-071 Issued: 4121/00 Parcel Number: 989704201
Job Address: Water and Filmore Streets. South Side Zoning: CIII Type: VV=N Occupancy: B
Total Occupant Load: N/C Nature of Work: Replace existintt transit shelter
Owner: Jefferson Transit Authority Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
RF.nTJTRED INSPECTIONS
APPROVED/DATE
DEMOLITION
Demolition materials shall be transported to the
Jefferson County Landfill or other approved facility
in accordance with all state and local laws and
ordinances
• `~
~~~-,ice"
J 13t ?a..~
CONCRETE
Anchor Boot System @ Posts
- anchor boot c~~~
- wedge anchors
3(` 2~°~
FRAMING
Internal Connections
- Rivets
- Frame Clips
~ ~~
- Hex Bolts
Window Safety Glazing 3l '20<•~
Page 1 of 2
Building Permit #BLDOp-071
FINAL
Barrier-Free
Building
GENERAL CONDITIONS
1. Contractors working on this project are required to Gave a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construMion is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3. A
minimum of twenty-four hours notice is required Public Works approval must be received prior to
scheduline the Buildine Department's final inspection
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits ezpire if no progress has been made within siz months, or if no inspections are done
by the Building Department within one year.-Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department ~ 379-3208 prior to making changes to the approved plans,
10. POST THIS PERMIT ONSITE WITH THE APPROVED PLANS.
Page 2 of 2
~.
Watemun & Katz Building
(SI Quincy Streel Suite 301
Pal Townsend, WA98368
(Phone) 379-3208 (Fax) 383-7673
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
TffiS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOO-~71 Issued: 4121100 Parcel Number: 989704201
Job Address: Water and Filmore Streets, North Side Zoning: CIII Type: V_N Occupancy: B
Total Occupant Load: N/C Nature of Work: Reulace existine transit shelter
Owner: Jefferson Transit Authority Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
APPROVED/DATE
DEMOLITION
Demolition materials shall be transported to the
Jefferson County Landfill or other approved facility
in accordance with all state and local laws and
ordinances
~~~.
~~3t ~~'
CONCRETE
Anchor Boot System @ Posts
- anchor boot plc
- wedge anchors
S ~3~ ~.~
FRAMING
Internal Connections
- Rivets
- Frame Clips
°~~`~~
= Hex Bolts ~~Zow
'''
Window Safety Glazing r
Page 1 of 2
Building Pamil #BLD00-071
RE UIRED INSPECTIONS APPROVED/DATE
FINAL
Barrier-Free pE~
Building I31 ~~a°
GENERAL CONDITIONS
1. Contractors working on this projeM are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
C~
4. Owner or owner's agent shall review and oversee correMion of any and all deficiencies noted by required .
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection caI1385-2294, press 3. A
minimum of twenri-four hours notice is required. Public Works aonroval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department rah 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
~_
Page 2 of 2
Walermm & Katz Building
181. Quinry Street Suite 301
PM Townsend, WA98368
(Phone) 379-3208 (Faz) 385-7673
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD ',
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDOO-071 Issued: 4/21100 Parcel Number: 989704201
Job Address: Water and Ouincy Streets Zoning: CIII Type: V_N Occupancy: B
Total Occupant Load: N/C Nature of Work: Replace existing transit shelter
Owner: Jefferson Transit Authority
Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
RFCITTTRF.T) TNCPF.('TTnNR
APPROVED/DATE
DEMOLITION
Demolition materials shall be transported to the
Jefferson County Landfill or other approved facility
in accordance with all state and local laws and
ordinances
Q ~r_ p ~
V ~ ~
~3l ~ 2~
CONCRETE
Anchor Boot System @ Posts
- anchor boot ~ ~~ ~~
- wedge anchors S I3~I2o~
FRAMING
Internal Connections
- Rivets
- Frame Clips /nt
~~~ ~~1~
- Hex Bolts
(
Window Safety Glazing S3i
'~5°°
Page 1 of 2
Building Permit NBLD00-071
FINAL
Barrier-Free
Building
6r- ~111~
~'I ~( ~~~
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-oi--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected For Public Works inspection call 385-2294, press 3. A
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within siz months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active
9. Revisions require submittal 8c approval prior to making changes in the field. ContaM the Building
Department Q 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Page 2 of 2