Loading...
HomeMy WebLinkAboutBLD00-063Waterman & Ksh au8dieg 181 Quinq street, Suite 301 Port Tow~naend, WA 98368 Phone: 360J79J206 Fu 360JB5-7675 CITY OF PORT TOWNSEND i CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION STTE Call 385-2294 for Inspection Permit Number: BLDOO-O63 Issued: 4113100 Parcel Number: 992300045 Job Address: 1476 West U Street Zoning: R-11 Type: VV=N Occupancy: RR_3 Total Occupant Load: add 1 Nature of Work: Sunroom Addition to Single-family Dwellin¢ Owner: Irene Denton/Jav Campbell Contractor: Townsend Builders. Inc. GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMTTS REOUII2ED: Electrical -Contact Labor & Industries @ 360-417-2702 RF[1TTTRF.T) TN.CPF.("TT(1NC APPRnVF;T1/nATF. TEMP EROSION & SDM'T CONTROL See General Condifron #2 Silt Fence as needed Drive Off Mat per attached details FOOTINGS Setbacks ~~ ~S~o~ 1 '1/ Footings "~, Forms Reinforcement FOUNDATION Stem Wall / r / Z~~~ `'('l nn 1 ' 1/ Forms ~ Reinforcement Anchor Bolts w/ 2" x 2" x 3/16" square washers Vents - 3 required Crawl Access Alternate braced wall panel (AB WP) holdowns Ca1148 hours before yoddig for utility line locates 1-800-424-5555 Page 1 of 3 Building Permit #BLD00.063 REQUIRED INSPECTInN~ appunvF.nme•rF FLOOR FRANIING Joists - n ,//2~/~~ ('~/ Blocking y~ l "` Positive Connections Treated Wood to Concrete Anchor Bolts & Washers Foundation Vents - 3 required FRAMING -sunroom addition is unheated space; contractor requests verification of insulation and U- factors for possible future heated space Walls C/~~ „ n J f ~ ( / Alternate Braced Wall Panels ` ~ Roof -Engineered ridge beam Rafter Venting - @ soffit Ceilings Posts, beams & headers Windows -safety glazing Windows Ufactor - NFRC window sticker must be on windows, skylights & doors at inspection time Air Seal Doors U factor Rafter/Truss Positive Connection Fireblocking Weather Resistive Barrier INSULATION -sunroom addition is unheated; contractor requests documentation of insulation for future heated space Fill newly created wall cavities in house from installation of SGD to replace existing windows Floor Wall Ceiling/Roof Baffles Vapor Barrier Crawl space - 6 mil black poly DRY WALL NAILING Walls s./~/~~ /~~ / !K Ceiling . Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 Building Permit #BLDOOA63 FINAL house Number -verify 5" numbers ////)/O ~ /~n Smoke Detectors throughout per UBC; one in each ~// j 'v' ~/\ sleeping room and in each hallway/area leading to sleeping rooms with minimum of one on each floor Final -Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced. wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Departments final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval rior to making changes in the field. Contact the Building Department at 379-3208 rior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 t \.