CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD~~-~62
Job Address: 817 Water Street
Total Occupant Load: N/C
Owner: Mauricio Cisneros
385-1931 (El Salape 379-9343)
Issued: 4/18/00 Parcel Number: 989700803
Zoning: CIII Type: N/C Occupancy: N/C
Nature of Work: Install Tvae I Hood with Make-uo Air Unit
and Exhaust Fan
Contractor: Alpine Fire and Safety Systems. Inc.
36022-7191
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries Qa 360-417-2702
Mechanical- Permit required for cooking appliance installation, propane piping and tank location.
Building Permit- Required for Type 1 Hood fire suppression system.
Plumbing Permit-Required for installation of grease trap.
MECHANICAL
Appliance/Exhaust Interlock
Exhaust Outlet Clearance - 2' above roof,• 5' other
Type I Duct Gage
Duct Joints/Seams - continuous liquid-tight weld
Grease Duct Supports - no penetration of duct walls
Duct Slope -'/.: 12
Duct/Enclosure Separation - 3 "min.; 12"maz
Duct EnclosureJShaft -one-hour construction
Cleanouts
Air Velocity - ISOOfpm - 2500 fpm
Duct/Combustible Clearance -18 "; 3 "from noncombustibles
Hood Flashing -less than 12 "from ceiling or walls requires
flashing with 22 gage steel
Duct Insulation -Make-up air: R-3.3
Grease Filters -see UMC 508.5 and notes on plans
Canopy Hood -installed per manufacturer's installation
instructions
Sj"2'~
Page 1 of 3
C
Blll~ltla pQ011[ ~~~~2
REQUIRED INSPECTIONS
APPROVED/DATF,
DRYWALL NAILING
Walls
Ceiling
1-hour shaft for Type 1 Hood.
s/Z'~~o~
FINAL
HPC -installation of rooftop equipment requires
inspection prior to screening, contact.7ohn McDonagh
® 379-5085; permit revision required prior to
construction of screening
Fire Department o ~ ~'` ^~ A
Electrical (I.&I) o ~ L~~ (
Plumbing -separate permit for grease trap
Mebhanical -separate permit for coolting
appliance/piping/tank o~
~ G (~
Building ~,BI zm..
GENERAL CONDITIONS
•
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished
2. Temporary erosion and sediment eontrol (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt
debris. Soils ezposed during construction shall be temporuily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with sceding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowas, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of nay and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed
6. 'The Building Department is unable to pass final inspection oa your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3. A
Page 2 of 3
M
CITY OF PORT TOWNSEND
s
COMMERCIAL HITCHEN INSPECTION AND TEST CERTIFICATE ~
THIS CARD MUST BE POSTED AT CONSTRUCTIONSITE
CALL 385-2626 FOR INSPECTION
Permit No. BLD00-062R-1 Issued: 5/16/00 Job Address: 817 Water Street
Nature of Work: Install Fire Suppression S sLtem Use of Building: Twe A-3
Owner: Mauricio Cisneros Contractor: amine Fire and Safety Systems. Inc.
385-1931 (EI Sarape 379-9343)
Contractor License Number: ALPINFS077RP
**Provide six liter K fire extinguisher**
REOUIItED INSPECTIONS
~~
t,
^ Extent of Coverage per plans
^ Discharge Nozzles (325° - 375° with orifice'/<" -'/z")
^ Automatic release device
^ Manual release device
^ Fuel or power disconnect
^ Manual shutoff
^ Manual reset
^ Fire resistive construction/protection requirements
^ Supply air
^ Duct enclosure
^ Exhaust outlet & clearance
^ Portable Fire Extinguisher (40-b:C within 30 feet)
ACCEPTANCE TEST
^ Trip Test
^ Automatic
^ Manual Release
^ Full /Power disconnect
Inspector
Date:
~: