CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION STTE
Ca11 3 85-229 4 for Inspection
Permit Number: BLDOO-O57 Issued: 4/11/0o Parcel Number: 940332001
Job Address: 657 McPherson Zoning: R-III Type: VV=N Occupancy: RR=3
Total Occupant Load: 9 Nature of Work: Set New Manufactured Home; add patio slab
Owner: Tammv Peselk Contractor: Future Homes/WAINS#1887
Contact: Mark @ 1-800-755-5231
****Installer: See Attached Installer Ta>?****
****Installation Manual to be on-site at time of inspection****
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REQUIItED:
Electrical -Contact Labor & Industries @ 360-417-2702
RE UIRED INSPECTIONS
APPROVED/DATE
C~
TEMP EROSION & SEDIMENT CONTROL
See general condition #2
Silt Fence as needed
Drive Off Mat to prevent sediment from leaving
the site
SLAB
Setbacks q y~,~
~~li~~f/V
Forms (!
Reinforcement
FLOOR FRANIING (prior to skirting)
Anchors
~/ZZ~Od
Steel Support Piers -Load-stamped and installed
per manufacturer's installation matmal;
clearance of IS"min. from lowest point of 1-
beam and the ground or footing for min of 75%
of area under home w/ 12"min. elsewhere
Area around home graded to provide runoff away
from home
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Pe~mlt #BLD00-057
REQUIRED INSPECTION$_ APPROVED/DATE
-.
PLUMBING:
Water Supply -Main shut-off valve (port or ball
valve) installed in water supply piping prior to
connection to home, min. '/. "diameter, same as
supply pipe
Pressure Reduction Valve if> 80 psi
Hose Bibs (backflow protection required)
Pipe Insulation -Outside & in crawl space
Pressure Test -100 p.s.i. for IS minutes
Pressure relief valve drain - to exterior of skirting,
exhaust downward between 6"and 24"above.
ground
Drainage Piping -sloped min. '/. "/ft.
/
~Z ~i/ ~(~
MECBAIVICAL
Ducts & Duct Insulation ~/2 ~a~
Dryer Exhaust -vented to outside. Extension into
crawl space requires venting through skirting
with no dips; follow dryer mrnnrfacturer's
instrucfions; total combined length of ducting not
to exceed 14' w/two 90° elbows.
VAPOR BARRIER
6 mil black poly ground cover (not required where
area under home is concrete slab floor with a
minimum thickness of 3 %J inches)
FINAL
Public Works Sign-Off
Electrical (L & I) Sign-Off
House Number
Plumbing
„^
Mechanical ~
lj' I
~ (
Entry Deck V
I
Final -Building
No holes or gaps greater than'/."allowed in
skirting.
Crawl space ventilation per installation mamral @
1/ISO (27 req'd); located close to corners, on at
least two opposing sides for cross ventilation.
Crawl Space access must provide access to all
areas under home; minimum 18" x 24 "; covered
with vinyl, pressure treated wood or metal.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3