HomeMy WebLinkAboutBLD00-041
Waterman & Katz Building
181 Quincy Street, Suite 301.
Port Townsen4 WA 98368
(360) 379-3208 Fax: (360) 385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: RLDOO-O41R-1 Issued: 813100 Parcel Number: 989710301
Job Address: 706 Franklin Street Zoning: R-11 Type: VV=N Occupancy: R~3
Total Occupant Load: N/C Nature of Work: Add dormer to existin>= roof framing.
Owner: KimballlLandis
Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RE UIRED INSPECTIONS
APPRnVF,D/)nATF,
FRAMING
' (i ~ d~J
oist attactunent
Collaz tie/Rafter/Ceilin G
FINAL
See original permit for final inspection.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Permit # BLDOO-O4tR-1
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down whi]e this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294, press 3. Measures shall include installation of silt
fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept
free of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching,
plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner ar owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any correMions are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3; a.
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building DepartmenNs final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits ezpire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. Revisions require review and approval prior to making changes in the field: Contact the Building
Department at 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
Waterman & Ketr, Bnilding
I31 Qninry Street, State 301
Porl Towmm~d, WA 96363
Phone: 36037937A8 Fex360J796973
CITY OF PORT TOWNSEND
CONSTRUCTION PERNIIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOO-O41 Issued: 3/23100 Parcel Number: 989710301
Job Address: 706 Franklin Street Zoning: R-11 Type: VV=N Occupancy: R_3
Total Occupant Load: N/C Nature of Work: Single-fami[y Dwelling Remodel
Owner: IGmbalULandis
Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REOUHiED:
Electrical -Contact Labor & Industries @ 360-417-2702
7?FllTTil2Ti'Tl TNCPF.f TT(IN,C'
APPRnVF:n/nATF.
DEMOLITION
Materials from demolition shall be transported to
the Jefferson County Landfill or other approved
location in accordance with all state and local laws
and ordinances
FOOTINGS
Setbacks ~Z~l~
Footings
Forms
Reinforcement
Interior Footings
Porch/Deck Piers
FOUNDATION
Stem Wall
Forms
Reinforcement
Anchor Bolts w/ 2" x 2" x 3/16" square washers
Vents - 9 square feet required or 13 vents
Crawl Access
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Building Permit #BLD00-041
REQUIRED TNSPF,C"TT(1NC ervunvFnm~T~
FLOOR FRAMING _ ~ ~ y v .
Girders - replace rotten members
Joists -replace rotten members ~/~~/~~
Blocking
Shield under Posts
Positive Connections
Girder to Concrete
Treated Wood to Concrete
Anchor Bolts & Washers
Foundation Vents
PLUMBING:
Rough-In (D-V-T & Clean Outs)
'~! Z s ~
Water Supply
Hose Bibs (backflow protection. req'd.)
Pipe Insulation - R-3
Pressure Reduction Valve if > 80 psi
Water Heater -seismic restraint @ I/3 points
with bottom strap minimum 4" above controls
MECHANICAL
Bathroom Fans - 50 cfm 7
/
Utility Room Fan - 50 cfm ~
~~Sr
Kitchen Fan - 100 cfm
Environmental Air Exhaust ducting with
backdraft dampers, insulation (R 4) and
terminus (located 3' from opening)
FRA)VIING
Walls ~ ~~~~
i
Ceiling l:~/
/
Roof
Attic Venting
Attic Access
Posts, beams & headers
Windows -escape if enlazging existing openings
Windows -safety glazing
Windows Ufactor - .40 or better, new windows
Skylight Ufactor - .58 or better
NFRC window sticker must be on
windows & skylights of inspection lime
Air Seai
Fireblocking
Weather Resistive Barrier
Ca1148 hours before you dig for utility tine locates
1-800-424-5555
Page 2 of 4
~.
•
•
•
Building Pmni[ #BLD00-041
RF.(1TTTRF.T1 TN5PF.CTIONS APPROVED/DATE
INSULATION
Floor (fill existing cavities)
Wall (fill exposed/new cavities)
Ceiling (will blow attic if no existing insulation )
Baffles
Vapor Barrier: vapor barrier paint
Crawl space - 6 mil black poly, laps seams 1Z"
~/~~/a~
DRY WALL NAII,ING
Walls ®~~~~~ ~~
Ceiling
Enclosed Usable Space Under Stairs
FINAL
House Number -check for 5" numbers , O/~~/~~~ ~ n
cl y~ (`'f
/
Plumbing ~
Mechanical
Vapor Bamer Paint certificate
Smoke Detectors throughout per UBC: one in
each sleeping room and in each hallway/area
leading to sleeping rooms with a minimum of one
on each floor
Final -porches and decks
Final -Building
GENERAL CONAITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt
fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept
free of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching,
plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdawns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
Call 4$ hours before you dig for utility line locates
I-800-424-5555
Page 3 of 4
Building Permit #BLD00-041
~=
i
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits ezpire if no progress has been made within siz months, or if no inspections are
done by the Building Department within one year. Coil for' at least one inspection per year to keep
your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department at 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4