HomeMy WebLinkAboutBLD00-022~e
W o4rmno & Katz BuiWlne
181 Quinry Strte4 Su14301
Port Towotend, WA 98368
PMne: 3603793208 Poz 3603794923
•
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385=2294 for Inspection
Permit Number: BLDOO-O22 Issued: 2/17/0o Parcel Number: 974-100-903 & 974-100.904
Job Address: 1606 Tav lor Street Zoning: RR=II Type: VV=N Occupancy: RR=3
Total Occupant Load: 4 Nature of Work: Addition to Single-Family Dwelling
Owner: Jan. & John Zimmer
Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REOUIItED:
Electrical -Contact Labor & Industries @ 360-417-2702
REQUIRED INSPECTIONS
APPROVED/DATE
TEMP EROSION & SDM'T CONTROL
See General Condition #2
Silt Fence as needed
Drive Off Mat per attached details
FOOTINGS
Setbacks ),y2$~ ~ / /
(/l'/ U~
Footings ll`
Forms
Reinforcement
FOUNDATION
Stem Wall
Forms
Reinforcement
Anchor Bolts w/ Z" x 2" x 3/16" square washers
Vents - 5 required
Crawl Access
Beam Pocket
Alternate braced wall panel (ABWP) holdowns
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Building Permit NBL1N10-022
REQUIRED INSPECTIONS APPROVED/DATE
FLOOR FRAMING
NOTE: Engineered plan to be on-site @
time of inspection
Girders
Joists -
Blocking
Shield under Posts
Positive Connections
Girder to Concrete
Treated Wood to Concrete
Anchor Bolts & Washers
PLUMBING:
Rough-In (D-V-T & Clean Outs).
Water Supply
Hose Bibs (backflow protection required.)
Pipe Insulation - R-3.
Pressure Reduction Valve if> 80 psi
MECHANICAL
Whole House Fan -Master Bath
~7/OL
Environmental Air Exhaust ducting, insulation ~
(R-4) and terminus (located 3' from opening)
FRAMING
Walls
?J/Z'//~
Sheer Wall Nailing /c
Alternate Braced Wall Panel
Roof -Engineered plan to be on-site at
time of inspection
Attic Venting -air baffle
Ceilings
Posts, beams & headers
Windows -egress
Windows -safety glazing
Windows Ufactor - .39 or better, new windows
NFRC window sticker must be on
windows & doors at inspection time
Air Seal
Fresh Air -Wall Ports Required
Doors Ufactor - .20 max.
Rafter/Truss Positive Connection
Fire Blocking
Weather Resistive Barrier
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
Building Pmnii #BLDOOd22
RF(ITTTRF.n TNSPFC'TiONS
INSULATION
30
Fl
R ~ , J„Q~, , ~ ~'~~ 90Y
~t/r
'l'y
;
)
oor (
- cC,ur ,, `
p
Wall (R-14 )
Ceiling (R-38 )
Vapor Bamer
Crawl space - 6 mil. black poly
DRY WALL NAILING , / ~'/ ~ ~
7
Wails
Ceiling
Interior Braced Wall Panels
FINAL
House Number
Plumbing
Mechanical
Smoke Detectors
*Battery powered OK in existing
construction
Final -Building
APPROVED/DATE
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & fndustries contractor's
reeistration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut dawn while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected
prior to beginning canstrucion; cat1385-2294, press 3. Measures shall include installation of silt
fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept
free of dirt and debris. Soils ezposed during construction shall be temporarily stabilized with mulching,
plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required aker any corrections are completed.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Building Permit #BI,D00-022 '
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3;~
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. POST THIS PERMIT ONSITE WITH THE APPROVED PLANS.
~-w-
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 4 of 4