HomeMy WebLinkAboutBLD00-019City of PoR Townsend/BCD
Waterman & Kafz Building
181 Quincy Sheet Suite 301
Port Townsend, WA98368
Phone (360}379.3208 Fax (360) 385-7675
CITY OF PORT TOWNSEND
~~
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Cal1385-2294 for Inspection
Permit Number: BLDOO-O19 Issued: 02/16/00 Parcel Number: 948000901
Job Address: 1547 Umatilla Avenue Zoning: R-11 Type: V=N Occupancy: R^3
Total Occupant Load: 3 additional Nature of Work: Sin ¢le-family Dwellin ¢ Addition
Owner: Anthony 8c Kathleen Lombardy Contractor: Steve Greenwood
GENERAL CONDITIONS APPLX -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
REniJIRED INSPECTIONS
APPROVED/DATE
TEMP EROSION AND SDM'T CONTROL
See General Condition #2
Graveled Construction Entrance
FOOTINGS
Setbacks ~ /~ ~ /~ ~
/ n ~J
r
j/
Footings J
/
((( l/
~
Forms
Reinforcement
Con ' us Interior Foo - gs
FOUNDATION
Engineered Holdowrrs at Bay Windaw
Z Z 9 f Q (~
Stem Wall
Forms
Reinforcement
Anchor Bolts w/ 2" x 2" x 3/16" square washers
Vents -10 required
Crawl Access
Beam Pockets
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 1 of 3
Pemit # BLD00-019
REOUIltED INSPECTIONS APPROVED/DATF,
FLOOR FRAbIING
Note.• Engineered floor joist plan shall be
available on-site at time of inspection G
3/ 0/dU ~ '
Girders
Joists
Blocking
Shield under Posts
Positive Connection
Girder to Concrete
Treated Wood to Concrete
Anchor Bolts & Washers
FDN Vents -10 required
FRANIING: n
Note: Engineered truss plan shall be available
on-site at time of inspection ~ r~~~o (~\']'Iy\J
Walls -Engineered shear wall at bay window
Roof
Rafter/Truss Positive Connection
Blocking
Attic Venting -ridge and eave
Ceilings
Posts, beams & headers -engineered header at
bay window
Windows Ufactor - 39 or better
NFRC window sticker must be on
windows at inspection time
Air Seal
Fresh Air Intake -window ports
Fire Blocking
Weather Resistive Barrier
INSULATION
~{/
J/v0
Floor (R 30) .
Wall (R-21 )
Ceiling (R-38 )_
Baffles
Vapor Barrier: paint
6 mil black poly in crawl space
DRY WALL NAILING y/~ /~
Walls
Ceiling
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Permit # BLD00-019
1L+
FINAL
House Number -check for 5" numbers at final -~/ ~ //
Insulation Certificate 5i ~~Q ~~ /vd,(~,'
Vapor Barrier Paint Certificate !!!
Smoke Detectors throughout; battery powered
okay in existing construction
Final -Building
GENERAL CONDITIONS
•
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; colt 385-2294, press 3. Measures shall include installation of silt
fencing and graveled construction entrance (see attached details). Soils ezposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized
with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for
protection of adjacent properties.
3. Atl elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has be
done by the Building Department within one year.
building permit active.
:n made within siz months, or if no inspections are
Call for at least one inspection per year to keep your
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department at 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca11 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
~~,