HomeMy WebLinkAboutBLD00-017ware~man ~ xatzs,dains
181 Q~voY 3tvxt, Suite 301
PortTaaauvd, WA 98368
Phone: (360)379-3208 Fax: (360)3"/9-6923
CITY OF PORT TOWNSEND
•
~J
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDOO-O17R-1 Issued: 3/22/00 Parcel Number: 988800301
dob Address: 764 Lawrence Street Zoning: R_II Type: VV=N Occupancy: R_3
Nature of Work: Tear off existing sunroom glass and rafters: replace rafters. glass (4 6°4° slidersl,
roof and wall sheathing• add 4 skvlights• expand deck per attached engineering
Owner: Andv Anderson
Contractor: Steve Wilfong
385-0830
GENERAL CONDITIONS APPLY -SEE LAST PAGE
RE UIRED INSPECTIONS
APPROVED/DATE
FOOTINGS -Deck Pier
Minimum 16" x 16" x 6" concrete footing
with 2 - #4 each way
Post Base - Simpson EPB66 per engineering
FRANIING per attached engineering:
Header - (2) 2" x 8" typical
Roof Rafters - Z" x 8" @ 24" o. c.
Hip Rafter - (2) 2" x 8" DF #2 or 4" x 8" HF #2
Roof Sheathing - %" OSB w/ 8d @ 4" o.c.
Wall Sheathing to solid mullions -'h" OSB w/
8d @ 4" o.c. typical @ front wall below new
windows & around window perimeter
Deck -all framing members to be pressure
treated ar oJ'wood naturally resistant to decay
- Joists
- Posts
- Positive Connections
- Treated Wood to Concrete
- Beam - 4" x 8" DF #2 w/ Simpson SIJL 46
- Ledger - 2" x 8"
- Guardrails
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Puma #BLD00.017R-1
FINAL
House Number
Smoke Detectors throughout per 1997 UBC: one ~ ~~
in each sleeping room and in each halUarea
leading to sleeping rooms with minimum one
detector on each floor; battery powered smoke
detectors adequate in existing construction
Final -Building '
GENERAL CONDTTIOI~IS
1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration
number and a City business license. Failure to provide proof of this documentation prior to work may
resuk in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with sreding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection priorto cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass fmal inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A
7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within s~z months, or if no inspections are done
by the Building Department within one year. Call .for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans. _
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
U
Waterman & x.r+Building
I81 Qwnry Street, 3uife 301
Port Towvend, Wq 98368
PMne: (360)379-3208 Faz: (360)379-6923
CITY OF PORT TOWNSEND
r~
L
n
CONSTRUCTION PERMIT & INSPECTION RECORD
Tffi5 CARD M[JST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDOO-O17 Issued: 2/03/00 Parcel Number: 988800301
Job Address: 764 Lawrence Street Zoning: RR=II Type: VV=N Occupancy: RR=3
Nature of Work: Replace three windows and one sliding door; add one new window
Owner: Andy Anderson
Contractor: Steve Wilfong
385-0830
GENERAL CONDITIONS APPLY -SEE LAST PAGE
UT~'l1TTT77FTl TNAPF('TT(TNC
APPRflVF:11/nATF,
FRAMING/FINAL:
Headers
Door -safety glazing in slider
Escape Windows - not applicable; no sleeping
rooms involved
Window/Door U factor - .40 or better (electric
heat)
NFRC window sticker must be on
windows at inspection time
Air Seal
FINAL
Souse Number
~~~~
Smoke Detectors throughout per 1997 UBC: one ~~ ~
in each sleeping room and in each halUazea
leading to sleeping rooms with minimum one
detector on each floor; battery powered smoke
detectors adequate in existing construction
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Permit llBLD00-017
GENERAL
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration •
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall 6e permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3. A
7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required for anon-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig. for utility line locates
1-800-424-5555
Page 2 of 2