BLD00-015
Warmom & KatzHuildiog 181 Quivry Strset, Sw1e 301 Port Townued, WA 96366 Phooe: (360) 379-3208 Faz: (360) 379-6923 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDOO-O15 Issued: 2/09/00 Parcel Number: 968-500-032 lob Address: 7~7 41'~ Street Zoning: PUD/R II Type: VV=N Occupancy: R-3/IJ-1 Total Occupant Load: 5/2 Nature of Work: Construct single-family residence with attached garage Owner; Dvrk & Miriam Lansdon Contractor: Campbell Construction GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REOUII2ED: Electrical -Contact Labor & Industries @ 360-417-2702 **Hours of construction limited to 8:00 a.m. to 6:00 p.m. Monday through Friday and prohibited on Saturdays, Sundays, and National Holidays** RFnTTIRF,I) INSPECTIONS APPROVED/DATE CLEARING/GRADING Tree removal prohibited for live trees at 6" diameter at breast height or more which aze located greater than 10 feet from building pad. TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS ~ Setbacks ~/~~/ Footings Forms Reinforcement Interior Footings Po s E Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 5 Permit N HLD00-015 RE UIRED INSPECTIONS APPROVED/DATE FOUNDATION Stem Wall Forms Reinforcement Beam Pockets (alternative) Anchor Bolts w/ 2" x Z" x 3/16" washers Foundation Vents -16 required Crawl Space Access (in floor) Alternate Braced Wall Panel Holdown Hazdwaze ////// / Z~,~ ~( DO 111 FLOOR FRAMING .Engineered BCljoist plan on-site at time of inspection ~ /~/O U Girders Cripple Wall Joists Blocking Shield under Posts Positive Connection Cruder to Concrete Beam Pockets Treated Wood to Concrete Anchor Bolts w/ 2" x 2"x 3/16" washers Foundation Vents - 16 required Crawl Space Access PLUMBING: Rough-In (D-V-T & Clean outs) / ~ /1 `C /Z 3 ©~ /v % Water Supply a t Gas Supply Hose Bibs (backflow protection required) Pipe Insulation (R-3) Pressure Reduction Valve if > 80 psi Water Heater Seismic Restraint - 2 places 18" above finished floor Pressure relief valve drain to exterior, terminate 6" - 24" above ground Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 5 Permit#BLD00.015 • RR(1TTTRF,n iNSPF,('TiONS APPROVED/DATE MECHANICAL Propane Furnace -manufacturer's installation cJ ~ 2~G~ instructions shall be on-site at time of inspection / /G Heat Duct & Duct Insulation (R-8) Whole House Fan -Hall Bathroom Source Specific Fans Environmental Air Exhaust ducting (w/back draft dampers), insulation (R-4) and terminus (located 3' from opening into building) FRAMING Walls r Alternate Braced Wall Panels /~ ~~~ c7 Ceilings Roof- see engineering for trussfwall connects'on Truss Positive Connection Blocking Attic Venting - eave and ridge Windows -escape Window safety glazing Windows Ufactor - .75 or better NFRC window sticker must be on windows at inspecfion time Air Seal Fresh Air Intake (Window Ports) Doors UFactor - .40 maximum Fire Blocking Weather Resistive Barrier INSULATION s Z Floor (R=19) Walls (R_19 ) Ceiling (R=30 ) Baffles Vapor Barrier: low perm. paint . Crawl space - 6 mil black poly DRY WALL NAILING r Walls f I Ceiling ~ 6 ~i Y~ 1 b I Ztltl~ Interior Braced Wall Panels Gazage/House Occupancy Sepazation -see attached engineering for garage wall specs Ca1148 hours before you dig for utility line locates I-800-424-5555 Page 3 of 5 Permit#BLD00-015 RE UIRED INSPECTIONS APPROVED/DATE DRAINAGE Tie-in with Lynnesfield master detention system LANDSCAPING Planting of one. tree required at corner of Lot 32 per PUDA condition #44(f) FINAL Fire Department (LPG) 7J~ ~~~~ ~ D Public Works Sign-Off / l.~ House Numbers Plumbing Mechanical/Heating Insulation Certificate Vapor Bamer Paint Certificate Smoke Detectors Final -Building 1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration number and a City business license. Failure to provide proof of this documentation prior to work rosy result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-af--way shall be kept free of dirt debris. Sails ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, haldowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspeMion ca11385-2294, press 3. A • Ca1148 hours before you dig for utility line locates 1-800.424-5555 Page 4 of 5 Permit #BLD00-0I S f 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page5of5