HomeMy WebLinkAboutBLD00-014Building Pamil #BLD00-014R-I
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
TffiS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD00-014 R-1
Job Address: 606 Roosevelt Street
Total Occupant Load: NC
Owner: Ann Landis
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF.CITTTRFT) TNCPF.C''TT()N~
Issued: 416/00 Parcel Number: 984600201
Zoning: R-11 Type: VV=N Occupancy: RR=3
Nature of Work: Revision: Add 2"d story eait & stair.
Contractor: CC & Sons (Dave Clevenger)
732-4731
APPROVED/DATE
FOOTINGS
Setbacks ~/1~~~ „n
~/
U
Footings 'C
Forms
Reinforcement
FRANIING
Engineered Shear Wall
~/~~w
Windows -safety glazing
Windows Ufactor - .68 or better
Air Seal
Doors Ufactor - . 68 or better
Rafter/Truss Positive Connection
Fireblocking
Weather Resistive Barrier
INSULATION
Wall(R-19)
Ceilin -30
DRY WALL NAII.ING
Walls
Ceilin
FINAL: See original permit for final inspection.
NOTE: This revision or occupancy of o,~ce does
not include approval of use of rental unit in main
house until conditions of CUP approval have been
met
2Ca1148 hours before you dig for utility line locates
1-800-424-5555
Building Permit #BLIKIO-014R-1
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's '
rer_istration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294, press 3. Measures shall'include installation of silt
fencing and graveled construction entrance (see attached details). Adjacent rights-af way shall be kept
free of dirt and debris. Soils ezposed during construction shall be temporarily stabilized with mulching,
plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
- 5. Re-inspection is required after any corrections are completed
6. TheBudding Department is unable to pass final inspection on your project unfit Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Departments final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within sia months, or if no inspections are
done by the Building Department within one year. Csll for at least one inspection per year to keep
your building permit active.
9. Revisions require submittal and approval urior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
L0. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
2Ca1148 hours before you dig for utility line locates
1-800-424-5555
Watermsn & %aR Buihll~
181 Quinry SlrM, Suite 301
Port Townoend~ WA 983fi8
Phom: 360J79JZ08 Fsz 360J79b921
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOO-O14 Issued: 2/09/0o Parcel Number: 984600201
Job Address: 606 Roosevelt Street Zoning: R-11 Type: V=N Occupancy: R=3
Total Occupant Load: add 1 Nature of Work: Home Office Addition to Sinele-family Dwellin¢
Owner: Ann Landis
Contractor: CC & Sons (Dave Cleveneer)
732-4731
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REOUIItED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF.(1TTTRF.TI TNCPF.C'TTnNC
APPRf7VF,D/DATE
TEMP EROSION & SDM'T CONTROL
See General Condition #2
Silt Fence as needed
Drive Off Mat per attached details or use existing
graveled drive
FOOTINGS
Setbacks
Footings
~ISlva o~ ~- .~.~2.
Forms
Reinforcement
UFER
FOUNDATION
Stem Wall
y/Z~~~ ~.
Forms
Reinforcement
Anchor Bolts - 5/8" x 12" anchor bolts @ 30" o.c.
at sheaz wall 1 per engineering
Engineered Holdowns
SLAB
R-10 Insulation
7
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Pagel of3
Building Permit #BLD00-014
REQUIRED INSPECTIONS APPROVED/DATE
PLUMBING
Gas Supply
MECHANICAL
LPG Stove
FRAMING
Walls n (~
Engineered Shear Wall ~/~~(, ~ 1~/' \V
Ceilings - 11 7/8 BCI 600 per engineering .
Roof
Attic Venting -none required, filled with rigid
Engineered Ledger
Windows -safety glazing
Windows Ufactor - .31 or better
NFRC window sticker must be on
windows & doors at inspection time
Air Seal S fZ 3 f~~ (~
l
Doors Ufactor - .36 or better ~
Rafter/Truss Positive Connection
Fireblocking
Weather Resistive Bamer '
INSULATION
Slab( R-10) ~/~ /'
S/z (~/00 d~. lJ
Wall (R-19) G
Ceiling (R-55 )
Vapor Barrier: paints
DRY WALL NAILING
Walls ( -
~ '`
~(, ~
Ceiling ~
"oe
b
FINAL
House Number -check at final
(~/L 5'/~Q-
Plumbing I
Mechanical
Vapor Barrier Paint Certificate
Smoke Detectors throughout existing
construction per 1997 UBC; battery powered
okay in existing constmction
Final -Building
NOTE.• Occupancy of office does not include
approval of use of rental unit in main house until
conditions of CUP approval have been met
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
I~
Building Permit #BLD00-014
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
reQistratian number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294, press 3. Measures shall include installation of silt
fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept
free of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching,
plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits ezpire it no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ONSITE WITH THE APPROVED PLANS.
,~' llc~ak woo ra,~.~-.~e~if
~~ ~ ~~ ~~
~" ~ '
~~~~z
~'~
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 3 of 3