HomeMy WebLinkAboutBLD00-013~z
w.tennd, & Kalzauilding
181 Qwn<Y suet, style 307
Port Townsend, WA 98368
Phone: (360) 379-3208 Fat: (360) 379.6923
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
PermilNumber. BLDUO-013
Job Address: 704 41'~ Street
Issued: 1/31100
Zoning: R_II Type: VV=N
Parcel Number: 965-500-061
Occupancy: R-3/U-1
Total Occupant Load: 412 Nature of Work: Construct single-family residence with
attached gara¢e
Owner: Llovd & Lunette Campbell Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
**Hours of construction limited to 8:00 a.m. to 6:00 p.m. Monday through Friday
• and prohibited on Saturdays, Sundays, and National Holidays. **
RF.(ITTTRF,T) TNSPF.CTTnNS
APPROVED/DATE
CLEARING/GRADING
Tree removal prohibited for live trees at 6" diameter
at breast height or more which are located greater
than 10 feet from building pad.
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS
Setbacks
-~ /~//~
Footings O
r !l
Forms
Reinforcement
Interior Footings
Porch Piers
,UEFA
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Pmni[ q BLD00-013
RE UIRED INSPECTIONS APPROVED/DATE
FOUNDATION
Stem Wall
Forms /~
~I~U~oU (' ~/
Reinforcement ~
Beam Pockets
Anchor Bolts w/ 2" x 2" x 3/16" washers
Foundation Vents - 10 requved
Crawl Space Access
Alternate Braced Wall Panel Holdown Hardware
~~ ,,~ ~- z Z ao
FLOOR FRAMING
Engineered BCI joist plan on-site at time of
inspection
f //„
Girders ~
/DO
/ r V
Joists l
Blocking
Shield under Posts
Positive Connection
Girder to Concrete
Beam Pockets
Treated Wood to Concrete
Anchor Bolts w/ 2" x 2"x 3/16" washers
Foundation Vents - 10 required
Crawl Space Access
PLUMBING:
Rough-In (D-V-T & Clean outs) ~ n
j/
~~ jla-Q ('
Water Supply ~
' r
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
Seismic Restraint - 2 places
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
18" above finished floor
MECHANICAL ~
Whole House Fan -Utility Room ~~ ~~ ~~~ ~f/i
~`'/
/
Source Specific Fans C
Environmental Air Exhaust ducting (w/ back draft
dampers), insulation (R-4) and terminus (located 3'
from opening into building)
Ca1148 hours before you dig for utility line locates
i-800-424-5555
Page 2 of 4
Pmnit p BI.D00-013
i
u>G'l1TTTRFTI TNCPF.(`TT(lNC APPRnVED/DATE
a`a~ vaaaa~~
FRAMING _ - -
~~f
Walls ~~~ ~~ / ~//
Alternate Braced Wall Panel ~~~ /ll `-' ~
Ceilings
Roof
Rafter Positive Connection
Attic Venting - eave and ridge
Windows -escape
Window safety glazing
Windows Ufactor - .40 maximum
NFRC window sticker must be on windows
at inspection time
Air Seal
Fresh Air Intake (Window or Wall Ports required)
Doors U-Factor - .20 maximum
Fire Blocking
Weather Resistive Barrier
INSULATION , L
Floor (R_30) 7
Walls (R=19 )
Ceiling (R=38 )
Baffles
Vapor Barrier: low perm. paint
Crawl space - 6 mil black poly
DRY WALL NAILING rJ/
Walls ~~
~~
/
!J
Ceiling /
Garage/House Occupancy Separation
Enclosed space under stairs
DRAINAGE
Tie-in with Lynnesfield master detention system
LANDSCAPING
Planting of one tree required at corner of Lot 61 per
PUDA condition #44(f)
FINAL (continued on next page) /^
///~ ,Q /'
Public Works Sign-0fl' /
S~ U~ ~'\ ~J
House Numbers
Plumbing
Mechanical/Heating
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Pmnit p BLD00-073
FINAL (continued) n
Insulation Certificate ~ L~/
Vapor Barrier Paint Certificate
Smoke Detectors
Final -Building
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A
minimum of twenty-four hours notice is required. Public Works saoroval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are. required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call far at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig Tor utility Tine locates
1-800-424-5555
Page 4 of 4