HomeMy WebLinkAboutBLD00-009,7~ Waterman & YaR BuBding 181 Quinq S[rcet~ Suae 301 PoR Townsend, WA 98368 Phone: 360J79J1B8 Fax 360J7%973 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDOO-OO9 Issued: 2111100 Parcel Number: 948312502 Job Address: 1024 Grant Street Zoning: R-11 Type: VV=N Occupancy: R_3 Total Occupant Load: 4 Nature of Work: Set New Manufactured Home to replace existing; add new decks/ramps Owner: John and Bettv Collev Contractor: Blvn Citv Builders/Installer # WAIN50851 Contact Pat @ 460-4202 (cell) ****Installer: See Attached Installer Tat=**** GENERAL CONDITIONS APPLY - SEE LAST PAGE SEPARATE PERMITS REOUII2ED: Electrical -Contact Labor & Industries @ 360-417-2702 RF,OTTiRED INSPECTIONS APPROVED/DATE TEMP EROSION & SDM'T CONTROL See general condition #2 Silt Fence as needed Drive Off Mat to prevent sediment from leaving the site SLAB Setbacks ,, n ~~Z/~d ~/ Forms Reinforcement FLOOR FRAMING (prior to skirting) Anchors Steel Support Piers -Load-stamped and installed per manufacturer's installation manual; clearance of I8"min. from lowestpoint of I-beam and the ground or footing for min. of 75% of area under home w/ 12"min. elsewhere Area around home graded to provide runoff away from home Cali 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 Peimlt kBLD00-009 RE UIRED INSPECTIONS APPROVED/DATE PLUMBING: Water Supply -Main shut-off valve (port or ~ ball valve) installed in water supply piping prior to connection to home, min. '/<"diameter, same as supply pipe Pressure Reduction Valve if> 80 psi Hose Bibs (backflow protection required) Pipe Insulation -Outside & in crawl space Pressure Test -100 p.s.i. for 15 minutes Pressure relief valve drain - to exterior of skirting, exhaust downward between 6"and 24" above ground Drainage Piping -sloped min. %.'%ft MECHANICAL Ducts & Duct Insulation Dryer Exhaust -vented to outside. F,xtension into crawl space requires venting through skirting with no dips; follow dryer manufacturer's instructions; total combined length of ducting not to exceed 14' w/ 2-90° elbows FRAMING: Entry Porch VAPOR BARRIER 6 mil black poly ground cover (not required where area under home is concrete slab floor with a minimum thickness of 3 %s inches) DRAINAGE -refer to approved plan issued with MIP00-008. Call Public Works at 385-2294 for inspection of infiltration trench prior to cover J Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 Perntit tIBLD00-009 REQUIREllINSYEC;'1'IUNJ AYYI(UVl~,ll/LAll~. FINAL Public Works Sign-Off Electrical (L & I) Sign-Oft' House Number ~~~ ~~ Plumbing Mechanical ~ .~ , Final -Building Porch No holes or gaps greater than '/: "allowed in skirting. Crawl space ventilation per installation manual @ 1/ISO (11 req'd.); located close to . corners, on at least two opposing sides for cross ventilation. Crawl space access must provide access to all areas under home; minimum 18"x 24"; covered with vinyl, pressure treated wood or metal. GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, 6oldowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspeMions. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Permit #BLD00-009 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits ezpire if no progress has been made within siz months,. or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit aMive. 9. POST THIS PERMIT ONSITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4