CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOO-OO9 Issued: 2111100 Parcel Number: 948312502
Job Address: 1024 Grant Street Zoning: R-11 Type: VV=N Occupancy: R_3
Total Occupant Load: 4 Nature of Work: Set New Manufactured Home to replace
existing; add new decks/ramps
Owner: John and Bettv Collev Contractor: Blvn Citv Builders/Installer # WAIN50851
Contact Pat @ 460-4202 (cell)
****Installer: See Attached Installer Tat=****
GENERAL CONDITIONS APPLY - SEE LAST PAGE
SEPARATE PERMITS REOUII2ED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF,OTTiRED INSPECTIONS
APPROVED/DATE
TEMP EROSION & SDM'T CONTROL
See general condition #2
Silt Fence as needed
Drive Off Mat to prevent sediment from leaving
the site
SLAB
Setbacks ,, n
~~Z/~d ~/
Forms
Reinforcement
FLOOR FRAMING (prior to skirting)
Anchors
Steel Support Piers -Load-stamped and installed
per manufacturer's installation manual; clearance
of I8"min. from lowestpoint of I-beam and the
ground or footing for min. of 75% of area under
home w/ 12"min. elsewhere
Area around home graded to provide runoff away
from home
Cali 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Peimlt kBLD00-009
RE UIRED INSPECTIONS APPROVED/DATE
PLUMBING:
Water Supply -Main shut-off valve (port or ~
ball valve) installed in water supply piping prior
to connection to home, min. '/<"diameter, same as
supply pipe
Pressure Reduction Valve if> 80 psi
Hose Bibs (backflow protection required)
Pipe Insulation -Outside & in crawl space
Pressure Test -100 p.s.i. for 15 minutes
Pressure relief valve drain - to exterior of
skirting, exhaust downward between 6"and 24"
above ground
Drainage Piping -sloped min. %.'%ft
MECHANICAL
Ducts & Duct Insulation
Dryer Exhaust -vented to outside. F,xtension
into crawl space requires venting through skirting
with no dips; follow dryer manufacturer's
instructions; total combined length of ducting not
to exceed 14' w/ 2-90° elbows
FRAMING:
Entry Porch
VAPOR BARRIER
6 mil black poly ground cover (not required
where area under home is concrete slab floor
with a minimum thickness of 3 %s inches)
DRAINAGE -refer to approved plan issued
with MIP00-008. Call Public Works at 385-2294
for inspection of infiltration trench prior to cover
J
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
Perntit tIBLD00-009
REQUIREllINSYEC;'1'IUNJ AYYI(UVl~,ll/LAll~.
FINAL
Public Works Sign-Off
Electrical (L & I) Sign-Oft'
House Number ~~~ ~~
Plumbing
Mechanical ~ .~ ,
Final -Building
Porch
No holes or gaps greater than '/: "allowed in
skirting.
Crawl space ventilation per installation
manual @ 1/ISO (11 req'd.); located close to .
corners, on at least two opposing sides for cross
ventilation.
Crawl space access must provide access to all
areas under home; minimum 18"x 24"; covered
with vinyl, pressure treated wood or metal.
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt
fencing and graveled construction entrance (see attached details). Soils ezposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized
with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for
protection of adjacent properties.
3. All elements of engineering including nailing, 6oldowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspeMions.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Permit #BLD00-009
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits ezpire if no progress has been made within siz months,. or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit aMive.
9. POST THIS PERMIT ONSITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4